In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20 μHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.01) fm s-2/Hz above 2 mHz and (6±1)×10 fm s-2/Hz at 20 μHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency.

Beyond the Required LISA Free-Fall Performance: New LISA Pathfinder Results down to 20 μhz / Armano, M., Audley, H., Baird, J., Binetruy, P., Born, M., Bortoluzzi, D., Castelli, E., Cavalleri, A., Cesarini, A., Cruise, A.M., Danzmann, K., De Deus Silva, M., Diepholz, I., Dixon, G., Dolesi, R., Ferraioli, L., Ferroni, V., Fitzsimons, E.D., Freschi, M., Gesa, L., et al.. - In: PHYSICAL REVIEW LETTERS. - ISSN 0031-9007. - 120:6(2018). [10.1103/PhysRevLett.120.061101]

Beyond the Required LISA Free-Fall Performance: New LISA Pathfinder Results down to 20 μhz

Bortoluzzi, D.;Castelli, Eleonora;Cesarini, A.;Dolesi, R.;Ferraioli, L.;Ferroni, V.;Gibert, F.;Giusteri, R.;Hueller, M.;Liu, L.;Pivato, P.;Russano, G.;Vetrugno, D.;Vitale, S.;Wass, P. J.;Weber, W. J.;
2018-01-01

Abstract

In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20 μHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.01) fm s-2/Hz above 2 mHz and (6±1)×10 fm s-2/Hz at 20 μHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency.
2018
6
Armano, M.; Audley, H.; Baird, J.; Binetruy, P.; Born, M.; Bortoluzzi, D.; Castelli, Eleonora; Cavalleri, A.; Cesarini, A.; Cruise, A. M.; Danzmann, K...espandi
Beyond the Required LISA Free-Fall Performance: New LISA Pathfinder Results down to 20 μhz / Armano, M., Audley, H., Baird, J., Binetruy, P., Born, M., Bortoluzzi, D., Castelli, E., Cavalleri, A., Cesarini, A., Cruise, A.M., Danzmann, K., De Deus Silva, M., Diepholz, I., Dixon, G., Dolesi, R., Ferraioli, L., Ferroni, V., Fitzsimons, E.D., Freschi, M., Gesa, L., et al.. - In: PHYSICAL REVIEW LETTERS. - ISSN 0031-9007. - 120:6(2018). [10.1103/PhysRevLett.120.061101]
File in questo prodotto:
File Dimensione Formato  
PhysRevLett.120.061101.pdf

accesso aperto

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Creative commons
Dimensione 514.38 kB
Formato Adobe PDF
514.38 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/198812
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 410
  • ???jsp.display-item.citation.isi??? 367
  • OpenAlex 378
social impact