The LISA Pathfinder space mission is testing the critical experimental challenge for LISA by measuring the differential acceleration between two free-falling test masses inside a single co-orbiting spacecraft at a level of sub-femto-g for frequencies down to 0.1mHz. In LPF it is necessary that one test mass (TM) is electrostatically forced to follow the orbit of the other TM. This force represents a noise source in differential acceleration at frequencies below 1mHz. The free-fall mode experiment has been performed in order to reduce this source of noise: the actuation is limited to short impulses on one TM, so that it is in free fall between two successive kicks, while the other TM is drag-free. The free-fall mode thus provides a different technique for measuring the differential TM acceleration without the added force noise and calibration issues introduced by the actuator. Data analysis challenge is related to the presence of the kicks: they represent a high-noise contribution and need to be removed, thus leaving short gaps in data. This article presents preliminary data of the LPF free-fall measurement campaign and describes the three data analysis techniques developed to mitigate the presence of gaps.
The free-fall mode experiment on LISA Pathfinder: First results / Giusteri, R.; Armano, M.; Audley, H.; Auger, G.; Baird, J.; Bassan, M.; Binetruy, P.; Born, M.; Bortoluzzi, D.; Brandt, N.; Caleno, M.; Cavalleri, A.; Cesarini, A.; Cruise, M.; Danzmann, K.; de Deus Silva, M.; De Rosa, R.; Di Fiore, L.; Diepholz, I.; Dolesi, R.; Dunbar, N.; Ferraioli, L.; Ferroni, V.; Fitzsimons, E.; Flatscher, R.; Freschi, M.; Marrirodriga, C. Garcia; Gerndt, R.; Gesa, L.; Gibert, F.; Giardini, D.; Giusteri, R.; Grado, A.; Grimani, C.; Grzymisch, J.; Harrison, I.; Heinzel, G.; Hewitson, M.; Hollington, D.; Hoyland, D.; Hueller, M.; Inchauspe, H.; Jennrich, O.; Jetzer, P.; Johlander, B.; Karnesis, N.; Kaune, B.; Korsakova, N.; Killow, C.; Lobo, A.; Lloro, I.; Liu, L.; Lopez-Zaragoza, J. P.; Maarschalkerweerd, R.; Mance, D.; Martin, V.; Martin-Polo, L.; Martino, J.; Martin-Porqueras, F.; Madden, S.; Mateos, I.; Mcnamara, P. W.; Mendes, J.; Mendel, L.; Nofrarias, M.; Paczkowski, S.; Perreur-Lloyd, M.; Petiteau, A.; Pivato, P.; Plagnol, E.; Prat, P.; Ragnit, U.; Ramos-Castro, J.; Reiche, J.; Robertson, D. I.; Rozemeijer, H.; Rivas, F.; Russano, G.; Sarra, P.; Schleicher, A.; Shaul, D.; Slutsky, J.; Sopuerta, C. F.; Stanga, R.; Sumner, T.; Texier, D.; Thorpe, J. I.; Trenke, C.; Troebs, M.; Vetrugno, D.; Vitale, S.; Wanner, G.; Ward, H.; Wass, P.; Wealthy, D.; Weber, W. J.; Wissel, L.; Wittchen, A.; Zambotti, A.; Zanoni, C.; Ziegler, T.; Zweifel, P.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 840:1(2017), p. 012005. [10.1088/1742-6596/840/1/012005]
The free-fall mode experiment on LISA Pathfinder: First results
The LISA Pathfinder space mission is testing the critical experimental challenge for LISA by measuring the differential acceleration between two free-falling test masses inside a single co-orbiting spacecraft at a level of sub-femto-g for frequencies down to 0.1mHz. In LPF it is necessary that one test mass (TM) is electrostatically forced to follow the orbit of the other TM. This force represents a noise source in differential acceleration at frequencies below 1mHz. The free-fall mode experiment has been performed in order to reduce this source of noise: the actuation is limited to short impulses on one TM, so that it is in free fall between two successive kicks, while the other TM is drag-free. The free-fall mode thus provides a different technique for measuring the differential TM acceleration without the added force noise and calibration issues introduced by the actuator. Data analysis challenge is related to the presence of the kicks: they represent a high-noise contribution and need to be removed, thus leaving short gaps in data. This article presents preliminary data of the LPF free-fall measurement campaign and describes the three data analysis techniques developed to mitigate the presence of gaps.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/271754
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
4
1
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.