Abstract In the present research, a method based on admittance measurements able to assess total solids and fat contents (%) in nine different liquid whole egg products was set up. By means of a tetrapolar platinum cell connected to a signal conditioning circuit, an alternating current generator and a data acquisition system, the effect of 15 different combinations of frequencies of the oscillating field (10, 100, 500, 1000 and 5000 Hz) and input voltage levels (1, 1.5 and 2 V) on the estimation of the total solids and fat contents were analyzed. The influence of the temperature solution on the electrical measurements was also assessed. The best estimations were obtained at 1000 Hz and 1 V (R^2 = 0.998; SE = 0.14%) for the total solids content and at 5000 Hz and 1 V (R^2 = 0.995; SE = 0.19%) for the fat content. For both parameters, the measurements conducted at 10 Hz appeared affected by the polarization occurring at the electrodes-solution interface. The admittance of the liquid whole egg products linearly increased with the temperature, and a temperature coefficient θ at 20 °C of about 2.1 was calculated. These excellent results encourage an industrial application of the technique for a rapid and economic assessment of the total solids and fat contents in the liquid egg products.

Admittance measurements to assess the total solids and fat contents in liquid whole egg products / Ragni, L.; Berardinelli, A.; Cevoli, C.; Sirri, F.. - In: JOURNAL OF FOOD ENGINEERING. - ISSN 0260-8774. - STAMPA. - 107:2(2011), pp. 179-185. [10.1016/j.jfoodeng.2011.06.026]

Admittance measurements to assess the total solids and fat contents in liquid whole egg products

A. Berardinelli;
2011-01-01

Abstract

Abstract In the present research, a method based on admittance measurements able to assess total solids and fat contents (%) in nine different liquid whole egg products was set up. By means of a tetrapolar platinum cell connected to a signal conditioning circuit, an alternating current generator and a data acquisition system, the effect of 15 different combinations of frequencies of the oscillating field (10, 100, 500, 1000 and 5000 Hz) and input voltage levels (1, 1.5 and 2 V) on the estimation of the total solids and fat contents were analyzed. The influence of the temperature solution on the electrical measurements was also assessed. The best estimations were obtained at 1000 Hz and 1 V (R^2 = 0.998; SE = 0.14%) for the total solids content and at 5000 Hz and 1 V (R^2 = 0.995; SE = 0.19%) for the fat content. For both parameters, the measurements conducted at 10 Hz appeared affected by the polarization occurring at the electrodes-solution interface. The admittance of the liquid whole egg products linearly increased with the temperature, and a temperature coefficient θ at 20 °C of about 2.1 was calculated. These excellent results encourage an industrial application of the technique for a rapid and economic assessment of the total solids and fat contents in the liquid egg products.
2011
2
Ragni, L.; Berardinelli, A.; Cevoli, C.; Sirri, F.
Admittance measurements to assess the total solids and fat contents in liquid whole egg products / Ragni, L.; Berardinelli, A.; Cevoli, C.; Sirri, F.. - In: JOURNAL OF FOOD ENGINEERING. - ISSN 0260-8774. - STAMPA. - 107:2(2011), pp. 179-185. [10.1016/j.jfoodeng.2011.06.026]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/229059
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 5
social impact