The paper investigates the effect of the interference due to spectral leakage on the frequency estimates returned by the Interpolated Discrete Fourier Transform (IpDFT) method based on the Maximum Sidelobe Decay (MSD) windows when harmonically distorted sine-waves are analyzed. The expressions for the frequency estimation error due to both the image of the fundamental tone and harmonics, and the frequency estimator variance due to the combined effect of both the above disturbances and wideband noise are derived. The achieved expressions allow us to identify which harmonics significantly contribute to frequency estimation uncertainty. A new IpDFT-based procedure capable to compensate all the significant effects of harmonics on the frequency estimation accuracy is then proposed. The derived theoretical results are verified through computer simulations. Moreover, the accuracy of the proposed procedure is compared with those of other state-of-the-art frequency estimation methods by means of both computer simulations and experimental results.

Impact of harmonics on the interpolated DFT frequency estimator / Belega, Daniel; Petri, Dario; Dallet, Dominique. - In: MECHANICAL SYSTEMS AND SIGNAL PROCESSING. - ISSN 0888-3270. - ELETTRONICO. - 66-67:(2016), pp. 349-360. [10.1016/j.ymssp.2015.05.025]

Impact of harmonics on the interpolated DFT frequency estimator

Petri, Dario;
2016-01-01

Abstract

The paper investigates the effect of the interference due to spectral leakage on the frequency estimates returned by the Interpolated Discrete Fourier Transform (IpDFT) method based on the Maximum Sidelobe Decay (MSD) windows when harmonically distorted sine-waves are analyzed. The expressions for the frequency estimation error due to both the image of the fundamental tone and harmonics, and the frequency estimator variance due to the combined effect of both the above disturbances and wideband noise are derived. The achieved expressions allow us to identify which harmonics significantly contribute to frequency estimation uncertainty. A new IpDFT-based procedure capable to compensate all the significant effects of harmonics on the frequency estimation accuracy is then proposed. The derived theoretical results are verified through computer simulations. Moreover, the accuracy of the proposed procedure is compared with those of other state-of-the-art frequency estimation methods by means of both computer simulations and experimental results.
2016
Belega, Daniel; Petri, Dario; Dallet, Dominique
Impact of harmonics on the interpolated DFT frequency estimator / Belega, Daniel; Petri, Dario; Dallet, Dominique. - In: MECHANICAL SYSTEMS AND SIGNAL PROCESSING. - ISSN 0888-3270. - ELETTRONICO. - 66-67:(2016), pp. 349-360. [10.1016/j.ymssp.2015.05.025]
File in questo prodotto:
File Dimensione Formato  
Impact of harmonics on the interpolated DFT frequency estimator.pdf

accesso aperto

Tipologia: Post-print referato (Refereed author’s manuscript)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 335.65 kB
Formato Adobe PDF
335.65 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/148549
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 20
social impact