Background. X-ray imaging is frequently used as diagnostic approach for scoliosis in children and adolescents. X-ray procedures are justified only when expected benefits exceed related risks. While benefits are well known to physicians, radiological risk awareness can be vague, impeding an optimal communication with patients' parents and possibly leading to discomfort and anxiety. Aim. To suggest a risk comparison approach for better communicating the radiological risks related to X-ray investigation of scoliosis. Methods. Starting point of the analysis is the Linear Non Threshold (LNT) assumption for radiation stochastic effect [1]: for effective doses (E) below 100 mSv, the probability of future stochastic damage is linearly related to E. This allows to add E from different sources to calculate a cumulative risk of health detriment. Data coming from literature were gathered to determine the average E delivered during X-ray investigation of scoliosis. Subsequently, the major natural sources of radiation, namely cosmic rays, 40K, 222Rn and other radionuclides, were considered. The average E due to these natural sources was compared with E due to the imaging of the vertebral column. Results. For a single standard scoliosis radiographic examination [2], E ranges from 0.2 to 0.35 mSv [3]. Therefore, the LNT assumption can be used. The main natural radiation source is 222Rn, which on average accounts for 1.2 mSv / y (range 0.2 - 10 mSv / y). Cosmic rays (0.4 mSv / y, range 0.3 - 1.0) and terrestrial gamma rays from other radionuclides (0.8 mSv / y, range 0.3 - 1.4) are additional sources of natural radiation. Moreover, flying from Europe to North America accounts for 0.03-0.05 mSv, and, because of the unavoidable presence of 40K, consuming 1,000 bananas or carrots accounts for approx. 0.1 mSv. Overall, 65% of the world population is expected to be exposed to an annual E between 1 and 3 mSv (average 2.4 mSv) [1]. Conclusions. Data coming from literature show how, on average, the effective annual dose coming from natural sources greatly exceeds the effective dose due to x-ray imaging for scoliosis. This information can play a key role in the relationship between physicians and patients. References: 1. United Nations Scientific Committee on the Effects of Atomic Radiation, "UNSCEAR 2000 Report Vol. 1, Sources And Effects Of Ionizing Radiation", Report to the General Assembly, with scientific annexes. 2. The American College of Radiology, ACR-SPR Practice Guideline for the Performance of Radiography for Scoliosis in Children (2009 revised). 3. M. Mogaadi, L. Ben Omrane, and A. Hammou, "Effective dose for scoliosis patients undergoing full spine radiography", Radiation Protection Dosimetry (2011), pp. 1-7.

A comparison approach to explain risks related to x-ray imaging for scoliosis / N., Pace; Ricci, Leonardo. - STAMPA. - (2012), pp. 59-59. (Intervento presentato al convegno 2012 SOSORT Meeting tenutosi a Milan, Italy nel 10th-12th May 2012) [10.1186/1748-7161-8-S1-O37].

A comparison approach to explain risks related to x-ray imaging for scoliosis

Ricci, Leonardo
2012-01-01

Abstract

Background. X-ray imaging is frequently used as diagnostic approach for scoliosis in children and adolescents. X-ray procedures are justified only when expected benefits exceed related risks. While benefits are well known to physicians, radiological risk awareness can be vague, impeding an optimal communication with patients' parents and possibly leading to discomfort and anxiety. Aim. To suggest a risk comparison approach for better communicating the radiological risks related to X-ray investigation of scoliosis. Methods. Starting point of the analysis is the Linear Non Threshold (LNT) assumption for radiation stochastic effect [1]: for effective doses (E) below 100 mSv, the probability of future stochastic damage is linearly related to E. This allows to add E from different sources to calculate a cumulative risk of health detriment. Data coming from literature were gathered to determine the average E delivered during X-ray investigation of scoliosis. Subsequently, the major natural sources of radiation, namely cosmic rays, 40K, 222Rn and other radionuclides, were considered. The average E due to these natural sources was compared with E due to the imaging of the vertebral column. Results. For a single standard scoliosis radiographic examination [2], E ranges from 0.2 to 0.35 mSv [3]. Therefore, the LNT assumption can be used. The main natural radiation source is 222Rn, which on average accounts for 1.2 mSv / y (range 0.2 - 10 mSv / y). Cosmic rays (0.4 mSv / y, range 0.3 - 1.0) and terrestrial gamma rays from other radionuclides (0.8 mSv / y, range 0.3 - 1.4) are additional sources of natural radiation. Moreover, flying from Europe to North America accounts for 0.03-0.05 mSv, and, because of the unavoidable presence of 40K, consuming 1,000 bananas or carrots accounts for approx. 0.1 mSv. Overall, 65% of the world population is expected to be exposed to an annual E between 1 and 3 mSv (average 2.4 mSv) [1]. Conclusions. Data coming from literature show how, on average, the effective annual dose coming from natural sources greatly exceeds the effective dose due to x-ray imaging for scoliosis. This information can play a key role in the relationship between physicians and patients. References: 1. United Nations Scientific Committee on the Effects of Atomic Radiation, "UNSCEAR 2000 Report Vol. 1, Sources And Effects Of Ionizing Radiation", Report to the General Assembly, with scientific annexes. 2. The American College of Radiology, ACR-SPR Practice Guideline for the Performance of Radiography for Scoliosis in Children (2009 revised). 3. M. Mogaadi, L. Ben Omrane, and A. Hammou, "Effective dose for scoliosis patients undergoing full spine radiography", Radiation Protection Dosimetry (2011), pp. 1-7.
2012
9th International Conference on Conservative Management of Spinal Deformities - 7th SOSORT Meeting - The Meeting Booklet
Milan, Italy
International Society on Scoliosis Orthopaedic and Rehabilitation Treatment (SOSORT)http://www.sosort.mobi/
A comparison approach to explain risks related to x-ray imaging for scoliosis / N., Pace; Ricci, Leonardo. - STAMPA. - (2012), pp. 59-59. (Intervento presentato al convegno 2012 SOSORT Meeting tenutosi a Milan, Italy nel 10th-12th May 2012) [10.1186/1748-7161-8-S1-O37].
N., Pace; Ricci, Leonardo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/95388
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact