Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), parameters of spectral estimator should be considered. In this study the surrogate data technique was introduced to define the level of significance of CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parameters of the adopted coherence estimator and on the record length, demonstrating the applicability of the method for all types of spectral estimator. This should favor its introduction for assessing the reliability of transfer function estimates in cardiovascular variability analysis.

Investigating the level of significance of the coherence function in cardiovascular variability analysis

Nollo, Giandomenico;Antolini, Renzo
2001-01-01

Abstract

Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), parameters of spectral estimator should be considered. In this study the surrogate data technique was introduced to define the level of significance of CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parameters of the adopted coherence estimator and on the record length, demonstrating the applicability of the method for all types of spectral estimator. This should favor its introduction for assessing the reliability of transfer function estimates in cardiovascular variability analysis.
2001
L., Faes; Nollo, Giandomenico; Antolini, Renzo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/73336
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
  • OpenAlex ND
social impact