Purpose: this study was conducted to compare the quantity of intercondylar bone removed during femoral box osteotomy for implantation of three contemporary posterior stabilized (PS) total knee arthroplasty designs: Sigma PS (DePuy), Vanguard (Biomet) and Persona (Zimmer). Methods: we compared the maximum volumetric bone resection required for the housing of the PS mechanism of these three designs. Bone removal by each PS box cutting jig was three-dimensionally measured. The differences between the three designs were analyzed by the Kruskal-Wallis test. The Mann- Whitney U-test was used for pairwise comparisons. The level of significance was set at p<0.05. Results: for small-size implants, the average box osteotomy volume of Persona was significantly smaller than the Vanguard and Sigma PS volumes (p=0.003). The mean difference between Vanguard and Sigma PS (p=0.01) was also significant. For medium size implants, the mean difference between Persona and Sigma PS (p=0.008) and the mean difference between Vanguard and Sigma PS (p=0.01) were statistically significant. For large size implants, the mean difference between Vanguard and Sigma PS (p=0.01) and the mean difference between Sigma PS and Persona (p=0.008) were statistically significant. Conclusions: irrespective of implant size, the Persona cutting jig always resected significantly less bone than did Vanguard and Sigma PS. Clinical Relevance: although this study does not establish any clinical relevance of removing more or less bone at primary TKA, its results suggest that if a PS design is indicated, it is preferable to select a model which resects less distal femoral bone.

Analysis of differences in bone removal during femoral box osteotomy for primary total knee arthroplasty / Graceffa, A., Indelli, P.F., Basnett, K., Marcucci, M.. - In: JOINTS. - ISSN 2282-4324. - 2:2(2014), pp. 76-80. [10.11138/jts/2014.2.2.076]

Analysis of differences in bone removal during femoral box osteotomy for primary total knee arthroplasty

Indelli P. F.
Secondo
;
2014-01-01

Abstract

Purpose: this study was conducted to compare the quantity of intercondylar bone removed during femoral box osteotomy for implantation of three contemporary posterior stabilized (PS) total knee arthroplasty designs: Sigma PS (DePuy), Vanguard (Biomet) and Persona (Zimmer). Methods: we compared the maximum volumetric bone resection required for the housing of the PS mechanism of these three designs. Bone removal by each PS box cutting jig was three-dimensionally measured. The differences between the three designs were analyzed by the Kruskal-Wallis test. The Mann- Whitney U-test was used for pairwise comparisons. The level of significance was set at p<0.05. Results: for small-size implants, the average box osteotomy volume of Persona was significantly smaller than the Vanguard and Sigma PS volumes (p=0.003). The mean difference between Vanguard and Sigma PS (p=0.01) was also significant. For medium size implants, the mean difference between Persona and Sigma PS (p=0.008) and the mean difference between Vanguard and Sigma PS (p=0.01) were statistically significant. For large size implants, the mean difference between Vanguard and Sigma PS (p=0.01) and the mean difference between Sigma PS and Persona (p=0.008) were statistically significant. Conclusions: irrespective of implant size, the Persona cutting jig always resected significantly less bone than did Vanguard and Sigma PS. Clinical Relevance: although this study does not establish any clinical relevance of removing more or less bone at primary TKA, its results suggest that if a PS design is indicated, it is preferable to select a model which resects less distal femoral bone.
2014
2
Graceffa, A.; Indelli, P. F.; Basnett, K.; Marcucci, M.
Analysis of differences in bone removal during femoral box osteotomy for primary total knee arthroplasty / Graceffa, A., Indelli, P.F., Basnett, K., Marcucci, M.. - In: JOINTS. - ISSN 2282-4324. - 2:2(2014), pp. 76-80. [10.11138/jts/2014.2.2.076]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/497470
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact