Purpose: The purpose of this study was to demonstrate closer-to-normal knee kinematics following primary total knee arthroplasty (TKA) performed establishing asymmetric gap balancing intraoperatively. Material and method: Two age-, sex-, BMI-matched groups of patients underwent medially stabilized TKA because of isolated knee disease. Group A (12 patients) underwent “unrestricted” kinematic alignment (uKA) according to Howell while group B (15 patients) received robot-assisted “simplified” KA (sKA) with an alignment goal (Hip-Knee-Ankle axis-HKA) ± 5° respect to the mechanical axis. Intraoperatively, in group B, the flexion gap at 90° was first set at an average of 1.5 mm (0–5 mm; SD 4.4 mm) tighter in the medial compartment with respect to the lateral; in the same way, the extension gap was then set at an average of 2.0 mm (0–4.5 mm; SD 3.1 mm) tighter in the medial compartment with respect to the lateral. All patients, including a non-arthritic cohort (group C: 5 controls) underwent gait analysis using an instrumented treadmill (WalkerView–WV) equipped with an instrumented belt armed with a 3D video camera. The WV software evaluated multiple spatiotemporal and kinematic parameters, including: (1) contact time (s); (2) knee ROM during gait cycle; (3) step length percentage with respect to total gait (%) and pure step length (cm). Statistical analyses included t-Test and ANOVA and were conducted by using SPSS. Results: At the final FU, significant differences were noted during gait between the two TKA groups (uKA-sKA) and the controls. Both TKA groups showed superior mean contact time on the surgical knee (uKA 1 s; sKA 0.97 s) as compared to the controls (0.72 s) (P = 0.002) while no differences were found between them (P = 0.11). TKA groups showed a lower, maximum ROM in the surgical knee (mean uKA 36º; mean sKA 49º) relative to the controls (mean 57º) (P < 0.05) but a statistical difference was found between them (P = 0.003). Both TKA groups showed a higher step length percentage with respect to the total gait and a shorter step length on the surgical side (uKA: mean 8.28% and mean step length 35.5 cm; sKA: mean 8.38% and mean step length 34.6 cm) in comparison to the controls (mean 3.38%; mean step length 71.4 cm) (P < 0.05) while no statistical differences were found between them. Conclusion: To our knowledge, this was the first study to exhibit the kinematic advantages of a slightly asymmetric gap balancing during KA TKA. Combining a medially-stabilized implant design and a surgical technique aiming to obtain a tighter medial compartment represents a promising approach to improve outcomes after TKA. Graphical Abstract: (Figure presented.)
Asymmetric gap balancing improves knee kinematic following primary total knee arthroplasty / Valpiana, P., Salvi, A.G., Ghirardelli, S., Bernardi, M., Petralia, G., Aloisi, G., Schaller, C., Indelli, P.F.. - In: ARTHROPLASTY. - ISSN 2524-7948. - 6:1(2024), pp. 291-297. [10.1186/s42836-024-00243-5]
Asymmetric gap balancing improves knee kinematic following primary total knee arthroplasty
Indelli, Pier Francesco
2024-01-01
Abstract
Purpose: The purpose of this study was to demonstrate closer-to-normal knee kinematics following primary total knee arthroplasty (TKA) performed establishing asymmetric gap balancing intraoperatively. Material and method: Two age-, sex-, BMI-matched groups of patients underwent medially stabilized TKA because of isolated knee disease. Group A (12 patients) underwent “unrestricted” kinematic alignment (uKA) according to Howell while group B (15 patients) received robot-assisted “simplified” KA (sKA) with an alignment goal (Hip-Knee-Ankle axis-HKA) ± 5° respect to the mechanical axis. Intraoperatively, in group B, the flexion gap at 90° was first set at an average of 1.5 mm (0–5 mm; SD 4.4 mm) tighter in the medial compartment with respect to the lateral; in the same way, the extension gap was then set at an average of 2.0 mm (0–4.5 mm; SD 3.1 mm) tighter in the medial compartment with respect to the lateral. All patients, including a non-arthritic cohort (group C: 5 controls) underwent gait analysis using an instrumented treadmill (WalkerView–WV) equipped with an instrumented belt armed with a 3D video camera. The WV software evaluated multiple spatiotemporal and kinematic parameters, including: (1) contact time (s); (2) knee ROM during gait cycle; (3) step length percentage with respect to total gait (%) and pure step length (cm). Statistical analyses included t-Test and ANOVA and were conducted by using SPSS. Results: At the final FU, significant differences were noted during gait between the two TKA groups (uKA-sKA) and the controls. Both TKA groups showed superior mean contact time on the surgical knee (uKA 1 s; sKA 0.97 s) as compared to the controls (0.72 s) (P = 0.002) while no differences were found between them (P = 0.11). TKA groups showed a lower, maximum ROM in the surgical knee (mean uKA 36º; mean sKA 49º) relative to the controls (mean 57º) (P < 0.05) but a statistical difference was found between them (P = 0.003). Both TKA groups showed a higher step length percentage with respect to the total gait and a shorter step length on the surgical side (uKA: mean 8.28% and mean step length 35.5 cm; sKA: mean 8.38% and mean step length 34.6 cm) in comparison to the controls (mean 3.38%; mean step length 71.4 cm) (P < 0.05) while no statistical differences were found between them. Conclusion: To our knowledge, this was the first study to exhibit the kinematic advantages of a slightly asymmetric gap balancing during KA TKA. Combining a medially-stabilized implant design and a surgical technique aiming to obtain a tighter medial compartment represents a promising approach to improve outcomes after TKA. Graphical Abstract: (Figure presented.)| File | Dimensione | Formato | |
|---|---|---|---|
|
VALPIANA.pdf
accesso aperto
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Creative commons
Dimensione
984.07 kB
Formato
Adobe PDF
|
984.07 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione



