Unicompartmental Knee Arthroplasty (UKA) is an effective surgical option for managing unicompartmental knee osteoarthritis; it represents 10% of all knee arthroplasties worldwide, increasing 32.5% annually in the United States alone. Despite evolution in surgical technique and implant design, success rate and long-term survivor- ship of UKA have been historically lower than Total Knee Arthroplasty (TKA). The most common causes of UKA failure lead-ing to revision are polyethylene wear, pro-gression of arthritis, aseptic loosening and patella-femoral symptoms due to poor patient selection in many cases. Historically, UKA revisions have presented technical challenges mainly related to man-aging residual bone defects and ligament insufficiency ultimately leading to knee instability: the fear of instability has often pushed surgeons to lower the threshold for an increase of the intra-articular level of constraint. Unfortunately, the use of more constrained implants requires sacrificing bone stock and has been related to higher rates of re-revision secondary to recurrence of aseptic loosening. Because of these chal- lenges, the authors developed a surgical technique that could combine balancing the knee during revision surgery with the use of the less constrained polyethylene option. To achieve this, we started evaluating a novel device (VERASENSE, Orthosensor, FL) designed to support soft tissue balancing during primary TKA. This intraoperative sensing technology dynamically quantifies intra-articular loads during TKA trial with the goal of correcting any residual imbal-ance in real time. Herein we propose a novel surgical technique, which might allow use of a primary TKA design charac-terized by a lower level of constraint, instead of a constrained or hinged revision knee system, during UKA revision. A key aspect of this technique is the use of sensing technology during intraoperative stability testing.
Sensor guided unicompartmental to total knee arthroplasty revision: Surgical technique / Indelli, P.F., Risitano, S., Pipino, G., Ghirardelli, S., Violante, B.. - In: ORTHOPEDIC REVIEWS. - ISSN 2035-8164. - ELETTRONICO. - 12:4(2020), pp. 182-185. [10.4081/or.2020.8806]
Sensor guided unicompartmental to total knee arthroplasty revision: Surgical technique.
Indelli, Pier Francesco
;
2020-01-01
Abstract
Unicompartmental Knee Arthroplasty (UKA) is an effective surgical option for managing unicompartmental knee osteoarthritis; it represents 10% of all knee arthroplasties worldwide, increasing 32.5% annually in the United States alone. Despite evolution in surgical technique and implant design, success rate and long-term survivor- ship of UKA have been historically lower than Total Knee Arthroplasty (TKA). The most common causes of UKA failure lead-ing to revision are polyethylene wear, pro-gression of arthritis, aseptic loosening and patella-femoral symptoms due to poor patient selection in many cases. Historically, UKA revisions have presented technical challenges mainly related to man-aging residual bone defects and ligament insufficiency ultimately leading to knee instability: the fear of instability has often pushed surgeons to lower the threshold for an increase of the intra-articular level of constraint. Unfortunately, the use of more constrained implants requires sacrificing bone stock and has been related to higher rates of re-revision secondary to recurrence of aseptic loosening. Because of these chal- lenges, the authors developed a surgical technique that could combine balancing the knee during revision surgery with the use of the less constrained polyethylene option. To achieve this, we started evaluating a novel device (VERASENSE, Orthosensor, FL) designed to support soft tissue balancing during primary TKA. This intraoperative sensing technology dynamically quantifies intra-articular loads during TKA trial with the goal of correcting any residual imbal-ance in real time. Herein we propose a novel surgical technique, which might allow use of a primary TKA design charac-terized by a lower level of constraint, instead of a constrained or hinged revision knee system, during UKA revision. A key aspect of this technique is the use of sensing technology during intraoperative stability testing.| File | Dimensione | Formato | |
|---|---|---|---|
|
UKA to TKA Sensor Paper.pdf
accesso aperto
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Creative commons
Dimensione
423.16 kB
Formato
Adobe PDF
|
423.16 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione



