Background: Organ-mounted robots address the problem of beating-heart surgery by adhering to the heart, passively providing a platform that approaches zero relative motion. Because of the quasi-periodic deformation of the heart due to heartbeat and respiration, registration must address not only spatial registration but also temporal registration. Methods: Motion data were collected in the porcine model in vivo (N = 6). Fourier series models of heart motion were developed. By comparing registrations generated using an iterative closest-point approach at different phases of respiration, the phase corresponding to minimum registration distance is identified. Results: The spatiotemporal registration technique presented here reduces registration error by an average of 4.2 mm over the 6 trials, in comparison with a more simplistic static registration that merely averages out the physiological motion. Conclusions: An empirical metric for spatiotemporal registration of organ-mounted robots is defined and demonstrated using data from animal models in vivo.

Beating-heart registration for organ-mounted robots / Wood, N. A.; Schwartzman, D.; Passineau, M. J.; Moraca, R. J.; Zenati, M. A.; Riviere, C. N.. - In: THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY. - ISSN 1478-5951. - 14:4(2018), pp. e1905.1-e1905.9. [10.1002/rcs.1905]

Beating-heart registration for organ-mounted robots

Zenati M. A.;
2018-01-01

Abstract

Background: Organ-mounted robots address the problem of beating-heart surgery by adhering to the heart, passively providing a platform that approaches zero relative motion. Because of the quasi-periodic deformation of the heart due to heartbeat and respiration, registration must address not only spatial registration but also temporal registration. Methods: Motion data were collected in the porcine model in vivo (N = 6). Fourier series models of heart motion were developed. By comparing registrations generated using an iterative closest-point approach at different phases of respiration, the phase corresponding to minimum registration distance is identified. Results: The spatiotemporal registration technique presented here reduces registration error by an average of 4.2 mm over the 6 trials, in comparison with a more simplistic static registration that merely averages out the physiological motion. Conclusions: An empirical metric for spatiotemporal registration of organ-mounted robots is defined and demonstrated using data from animal models in vivo.
2018
4
Settore MEDS-13/C - Chirurgia cardiaca
Settore INFO-01/A - Informatica
Wood, N. A.; Schwartzman, D.; Passineau, M. J.; Moraca, R. J.; Zenati, M. A.; Riviere, C. N.
Beating-heart registration for organ-mounted robots / Wood, N. A.; Schwartzman, D.; Passineau, M. J.; Moraca, R. J.; Zenati, M. A.; Riviere, C. N.. - In: THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY. - ISSN 1478-5951. - 14:4(2018), pp. e1905.1-e1905.9. [10.1002/rcs.1905]
File in questo prodotto:
File Dimensione Formato  
BEATING HEART REGISTRATION.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 15.72 MB
Formato Adobe PDF
15.72 MB Adobe PDF   Visualizza/Apri
1-5.pdf

Solo gestori archivio

Descrizione: part. 1
Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 8.97 MB
Formato Adobe PDF
8.97 MB Adobe PDF   Visualizza/Apri
6-9.pdf

Solo gestori archivio

Descrizione: part. 2
Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 6.48 MB
Formato Adobe PDF
6.48 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/476034
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex 3
social impact