If a perfusionist weans a patient off the heart lung machine (HLM) and the anesthesiologist has not re-started the ventilator, the patient will become hypoxic. The objective of this project was to create a redundant safety system of verbal and electronic communication to prevent failure to ventilate errors after cardiopulmonary bypass. This objective could be realized by building an electronic communication bridge directly between the HLM and ventilator. A software application was created to retrieve and interpret data from the pump and ventilator and trigger a programmed smart alarm. The software is able to interpret data from the pump and ventilator. When both are off simultaneously (defined as a pump flow of 0 L/min with a respiratory rate of 0 breaths/min), the application will raies an alarm. Communication between a pump and ventilator is possible, enabling the deployment of a safety system that could exist in the operating room (OR) as a standalone alarm. A device dataset can be used to optimize clinical performance of the alarm. The application could also be integrated into smart checklists and computer-assisted OR process models that are currently in development.

Establishing a ventilator–heart lung machine communication bridge to mitigate errors when weaning from bypass / Rance, G.; Arney, D.; Srey, R.; Goldman, J. M.; Zenati, M. A.. - In: THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY. - ISSN 0022-1058. - 51:3(2019), pp. 38-40.

Establishing a ventilator–heart lung machine communication bridge to mitigate errors when weaning from bypass

Zenati M. A.
Ultimo
2019-01-01

Abstract

If a perfusionist weans a patient off the heart lung machine (HLM) and the anesthesiologist has not re-started the ventilator, the patient will become hypoxic. The objective of this project was to create a redundant safety system of verbal and electronic communication to prevent failure to ventilate errors after cardiopulmonary bypass. This objective could be realized by building an electronic communication bridge directly between the HLM and ventilator. A software application was created to retrieve and interpret data from the pump and ventilator and trigger a programmed smart alarm. The software is able to interpret data from the pump and ventilator. When both are off simultaneously (defined as a pump flow of 0 L/min with a respiratory rate of 0 breaths/min), the application will raies an alarm. Communication between a pump and ventilator is possible, enabling the deployment of a safety system that could exist in the operating room (OR) as a standalone alarm. A device dataset can be used to optimize clinical performance of the alarm. The application could also be integrated into smart checklists and computer-assisted OR process models that are currently in development.
2019
3
Settore MEDS-13/C - Chirurgia cardiaca
Rance, G.; Arney, D.; Srey, R.; Goldman, J. M.; Zenati, M. A.
Establishing a ventilator–heart lung machine communication bridge to mitigate errors when weaning from bypass / Rance, G.; Arney, D.; Srey, R.; Goldman, J. M.; Zenati, M. A.. - In: THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY. - ISSN 0022-1058. - 51:3(2019), pp. 38-40.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/473494
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 5
social impact