BACKGROUND: Postcardiotomy heart failure is still the main cause of death in patients undergoing palliative surgery for end-stage dilative cardiomyopathy. New micro-axial flow ventricular assisting devices (LVAD) have been suggested in such cases. OBJECTIVE: Evaluate the effect of the new LVAD on short-term outcome of a patient admitted for end-stage heart failure. STUDY DESIGN: Case report. DATA SOURCES: One patient admitted for severe mitral regurgitation secondary to end-stage dilative cardiomyopathy and chronic atrial fibrillation (AF). INTERVENTION: Preoperative intraaortic balloon pump (IABP) insertion, mitral plasty with radiofrequency ablation of AF, microaxial flow LVAD support. RESULTS: The patient was unweanable from cardiopulmonary bypass until microaxial flow LVAD unloaded the left ventricle and restored adequate cardiac function. The patient was discharged home and is still well at 5 months folllow-up. CONCLUSIONS: The miniinvasive insertion and withdrawal, low anticoagulation protocols, and the possibility of coupling with IABP make the microaxial flow LVAD promising for patients with end-stage heart failure undergoing surgery.
Ventricular assistance with microaxial flow pump following mitral repair for dilated cardiomyopathy / Onorati, F., Cristodoro, L., Borrello, F., Esposito, A., Merola, S., Renzulli, A.. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - 29:(2006), pp. 591-595. [10.1177/039139880602900608]
Ventricular assistance with microaxial flow pump following mitral repair for dilated cardiomyopathy
Onorati F;
2006-01-01
Abstract
BACKGROUND: Postcardiotomy heart failure is still the main cause of death in patients undergoing palliative surgery for end-stage dilative cardiomyopathy. New micro-axial flow ventricular assisting devices (LVAD) have been suggested in such cases. OBJECTIVE: Evaluate the effect of the new LVAD on short-term outcome of a patient admitted for end-stage heart failure. STUDY DESIGN: Case report. DATA SOURCES: One patient admitted for severe mitral regurgitation secondary to end-stage dilative cardiomyopathy and chronic atrial fibrillation (AF). INTERVENTION: Preoperative intraaortic balloon pump (IABP) insertion, mitral plasty with radiofrequency ablation of AF, microaxial flow LVAD support. RESULTS: The patient was unweanable from cardiopulmonary bypass until microaxial flow LVAD unloaded the left ventricle and restored adequate cardiac function. The patient was discharged home and is still well at 5 months folllow-up. CONCLUSIONS: The miniinvasive insertion and withdrawal, low anticoagulation protocols, and the possibility of coupling with IABP make the microaxial flow LVAD promising for patients with end-stage heart failure undergoing surgery.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione



