The aim of this study is to evaluate if a simple intra-aortic balloon pump (IABP)-induced pulsatile perfusion reduces activation of coagulative system during cardiopulmonary bypass (CPB). Ninety-six patients undergoing preoperative IABP were randomized to nonpulsatile CPB with IABP discontinued during cardioplegic arrest (Group A) or IABP-induced pulsatile CPB (Group B). White blood cells (WBC), hematocrit (Ht), platelets (PLTs), International Normalized Ratio (INR), fibrinogen, activated partial thromboplastin time (aPTT), antithrombin III (AT-III) activity, and D-dimer were measured at the end of surgery (ES) and postoperatively. Chest drainage, need for reexploration, and transfusions were compared. Group B showed lower chest drainage (1st day P = 0.038; 2nd day P = 0.044), transfusions (P = 0.031), WBC (P < 0.05 at all time points), and INR (P < 0.05 at all time points), together with a higher Ht (P < 0.05 at ES, 12 h), platelets (P < 0.04 at all time points), fibrinogen (P < 0.05 at ES, 12 h, 24 h), and aPTT (P < 0.05 at all time points). AT-III activity lowered in Group A (P = 0.001 at ES, 12 h, 24 h), together with higher D-dimer levels (P < 0.05 at all time points). IABP-induced pulsatile perfusion ameliorates coagulative system activation following CPB.

Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass / Onorati, F., Esposito, A., Comi, M.c., Impiombato, B., Cristodoro, L., Mastroroberto, P., Renzulli, A.. - In: ARTIFICIAL ORGANS. - ISSN 0160-564X. - 32:6(2008), pp. 433-441. [10.1111/j.1525-1594.2008.00563.x]

Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass

Onorati, F;
2008-01-01

Abstract

The aim of this study is to evaluate if a simple intra-aortic balloon pump (IABP)-induced pulsatile perfusion reduces activation of coagulative system during cardiopulmonary bypass (CPB). Ninety-six patients undergoing preoperative IABP were randomized to nonpulsatile CPB with IABP discontinued during cardioplegic arrest (Group A) or IABP-induced pulsatile CPB (Group B). White blood cells (WBC), hematocrit (Ht), platelets (PLTs), International Normalized Ratio (INR), fibrinogen, activated partial thromboplastin time (aPTT), antithrombin III (AT-III) activity, and D-dimer were measured at the end of surgery (ES) and postoperatively. Chest drainage, need for reexploration, and transfusions were compared. Group B showed lower chest drainage (1st day P = 0.038; 2nd day P = 0.044), transfusions (P = 0.031), WBC (P < 0.05 at all time points), and INR (P < 0.05 at all time points), together with a higher Ht (P < 0.05 at ES, 12 h), platelets (P < 0.04 at all time points), fibrinogen (P < 0.05 at ES, 12 h, 24 h), and aPTT (P < 0.05 at all time points). AT-III activity lowered in Group A (P = 0.001 at ES, 12 h, 24 h), together with higher D-dimer levels (P < 0.05 at all time points). IABP-induced pulsatile perfusion ameliorates coagulative system activation following CPB.
2008
6
Onorati, F; Esposito, A; Comi, Mc; Impiombato, B; Cristodoro, L; Mastroroberto, P; Renzulli, A
Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass / Onorati, F., Esposito, A., Comi, M.c., Impiombato, B., Cristodoro, L., Mastroroberto, P., Renzulli, A.. - In: ARTIFICIAL ORGANS. - ISSN 0160-564X. - 32:6(2008), pp. 433-441. [10.1111/j.1525-1594.2008.00563.x]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/468555
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 29
  • OpenAlex 35
social impact