Objective: to analyze the physical and biological barrier characteristics of cotton fields used as a sterile barrier system after multiple use and processing cycles in the clinical practice. Method: an observational and longitudinal study to monitor and evaluate 100% cotton fabric used as a sterile barrier system in a medium-sized hospital. Samples were collected before use (after three washes) and at three, six, nine, 12 and 15 months of use and evaluated for the number, thickness and integrity of threads, weight, water absorption and wet penetration by microorganisms. Results: after 85 washes, the number of threads remained unchanged, and the shredded fibers and the water volume absorbed were increased. The microbiological test using the German standard methodology obtained a negative result and wet penetration by microorganisms did not show significant changes over time, although a percentage of the microbial cells passed through the double-layer samples. Conclusion: the physical properties of 100% cotton used as a sterile barrier system changed with use/processing cycles; however, these alterations did not significantly interfere with the results obtained by the tests performed on the microbiological barrier up to 85 washes.
Reuso de barreira estéril de tecido de algodão na prática clínica: estudo longitudinal observacional / Bouwman, Berendina Elsina; Costa, Dayane De Melo; Tessarolo, Francesco; Tipple, Anaclara Ferreira Veiga. - In: REVISTA LATINO-AMERICANA DE ENFERMAGEM. - ISSN 0104-1169. - 31:(2023). [10.1590/1518-8345.6645.3990]
Reuso de barreira estéril de tecido de algodão na prática clínica: estudo longitudinal observacional
Tessarolo, FrancescoPenultimo
;
2023-01-01
Abstract
Objective: to analyze the physical and biological barrier characteristics of cotton fields used as a sterile barrier system after multiple use and processing cycles in the clinical practice. Method: an observational and longitudinal study to monitor and evaluate 100% cotton fabric used as a sterile barrier system in a medium-sized hospital. Samples were collected before use (after three washes) and at three, six, nine, 12 and 15 months of use and evaluated for the number, thickness and integrity of threads, weight, water absorption and wet penetration by microorganisms. Results: after 85 washes, the number of threads remained unchanged, and the shredded fibers and the water volume absorbed were increased. The microbiological test using the German standard methodology obtained a negative result and wet penetration by microorganisms did not show significant changes over time, although a percentage of the microbial cells passed through the double-layer samples. Conclusion: the physical properties of 100% cotton used as a sterile barrier system changed with use/processing cycles; however, these alterations did not significantly interfere with the results obtained by the tests performed on the microbiological barrier up to 85 washes.| File | Dimensione | Formato | |
|---|---|---|---|
|
Bowman et al 2023_Reuso_de_barreira_esteril_de_tecido_de_algodao_final online.pdf
accesso aperto
Tipologia:
Post-print referato (Refereed author’s manuscript)
Licenza:
Creative commons
Dimensione
1.19 MB
Formato
Adobe PDF
|
1.19 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione



