Objective: to analyze the physical and biological barrier characteristics of cotton fields used as a sterile barrier system after multiple use and processing cycles in the clinical practice. Method: an observational and longitudinal study to monitor and evaluate 100% cotton fabric used as a sterile barrier system in a medium-sized hospital. Samples were collected before use (after three washes) and at three, six, nine, 12 and 15 months of use and evaluated for the number, thickness and integrity of threads, weight, water absorption and wet penetration by microorganisms. Results: after 85 washes, the number of threads remained unchanged, and the shredded fibers and the water volume absorbed were increased. The microbiological test using the German standard methodology obtained a negative result and wet penetration by microorganisms did not show significant changes over time, although a percentage of the microbial cells passed through the double-layer samples. Conclusion: the physical properties of 100% cotton used as a sterile barrier system changed with use/processing cycles; however, these alterations did not significantly interfere with the results obtained by the tests performed on the microbiological barrier up to 85 washes.

Reusing sterile cotton fabric barriers in the clinical practice: an observational and longitudinal study / Bouwman, Berendina Elsina; Costa, Dayane de Melo; Tessarolo, Francesco; Tipple, Anaclara Ferreira Veiga. - In: REVISTA LATINO-AMERICANA DE ENFERMAGEM. - ISSN 0104-1169. - 31:(2023). [10.1590/1518-8345.6645.3990]

Reusing sterile cotton fabric barriers in the clinical practice: an observational and longitudinal study

Tessarolo, Francesco
Penultimo
;
2023-01-01

Abstract

Objective: to analyze the physical and biological barrier characteristics of cotton fields used as a sterile barrier system after multiple use and processing cycles in the clinical practice. Method: an observational and longitudinal study to monitor and evaluate 100% cotton fabric used as a sterile barrier system in a medium-sized hospital. Samples were collected before use (after three washes) and at three, six, nine, 12 and 15 months of use and evaluated for the number, thickness and integrity of threads, weight, water absorption and wet penetration by microorganisms. Results: after 85 washes, the number of threads remained unchanged, and the shredded fibers and the water volume absorbed were increased. The microbiological test using the German standard methodology obtained a negative result and wet penetration by microorganisms did not show significant changes over time, although a percentage of the microbial cells passed through the double-layer samples. Conclusion: the physical properties of 100% cotton used as a sterile barrier system changed with use/processing cycles; however, these alterations did not significantly interfere with the results obtained by the tests performed on the microbiological barrier up to 85 washes.
2023
Bouwman, Berendina Elsina; Costa, Dayane de Melo; Tessarolo, Francesco; Tipple, Anaclara Ferreira Veiga
Reusing sterile cotton fabric barriers in the clinical practice: an observational and longitudinal study / Bouwman, Berendina Elsina; Costa, Dayane de Melo; Tessarolo, Francesco; Tipple, Anaclara Ferreira Veiga. - In: REVISTA LATINO-AMERICANA DE ENFERMAGEM. - ISSN 0104-1169. - 31:(2023). [10.1590/1518-8345.6645.3990]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/441116
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact