The present study aimed to design an electrochemical sensor for the detection of tinidazole (TN) by carbon nanotube electrode (CNTE) modified with dl-phenylalanine (DL-PA). The unmodified carbon nanotube electrode (UMCNTE) and poly (DL-PA) modified carbon nanotube electrode (P(DL-PA) MCNTE) were characterized by Scanning emission microscopy (SEM) images. Electrochemical techniques like cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV), were implemented to evaluate the efficiency of the developed electrode toward the detection of TN. The impact of pH on the modified electrode showed that the P(DL-PA) MCNTE gave a good voltammetric response at pH 3.5. The effect of accumulation time, scan rate, and variation of concentration of TN at the surface of the developed sensor was analyzed. The scan rate study showed that the reduction reaction of TN involves a two-electron transfer process and it is adsorption-controlled. The detection limit studies for CV and DPV gave good linearity in the linear range 0.6 μM to 100.0 μM and 3.0 μM to 100.0 μM respectively. The limit of quantification (LOQ) and limit of detection (LOD) concerning CV were found to be 0.65 μM and 0.19 μM respectively. The LOQ and LOD for DPV were calculated to be 0.33 μM and 0.10 μM respectively. The P(DL-PA) MCNTE showed good anti-interferent properties. The developed sensor has good stability, repeatability, and reproducibility for the analysis of TN. The P(DL-PA) MCNTE was successfully employed in the real sample analysis.

Application of Poly Dl-Phenylalanine Modified Carbon Nanotube Electrode for Sensitive and Selective Detection of Tinidazole / Moulya, K. P.; Manjunatha, J. G.; Aljuwayid, A. M.; Ataollahi, N.. - In: CHEMISTRYSELECT. - ISSN 2365-6549. - 2024, 9:24(2024), pp. 1-11. [10.1002/slct.202401843]

Application of Poly Dl-Phenylalanine Modified Carbon Nanotube Electrode for Sensitive and Selective Detection of Tinidazole

Ataollahi N.
2024-01-01

Abstract

The present study aimed to design an electrochemical sensor for the detection of tinidazole (TN) by carbon nanotube electrode (CNTE) modified with dl-phenylalanine (DL-PA). The unmodified carbon nanotube electrode (UMCNTE) and poly (DL-PA) modified carbon nanotube electrode (P(DL-PA) MCNTE) were characterized by Scanning emission microscopy (SEM) images. Electrochemical techniques like cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV), were implemented to evaluate the efficiency of the developed electrode toward the detection of TN. The impact of pH on the modified electrode showed that the P(DL-PA) MCNTE gave a good voltammetric response at pH 3.5. The effect of accumulation time, scan rate, and variation of concentration of TN at the surface of the developed sensor was analyzed. The scan rate study showed that the reduction reaction of TN involves a two-electron transfer process and it is adsorption-controlled. The detection limit studies for CV and DPV gave good linearity in the linear range 0.6 μM to 100.0 μM and 3.0 μM to 100.0 μM respectively. The limit of quantification (LOQ) and limit of detection (LOD) concerning CV were found to be 0.65 μM and 0.19 μM respectively. The LOQ and LOD for DPV were calculated to be 0.33 μM and 0.10 μM respectively. The P(DL-PA) MCNTE showed good anti-interferent properties. The developed sensor has good stability, repeatability, and reproducibility for the analysis of TN. The P(DL-PA) MCNTE was successfully employed in the real sample analysis.
2024
24
Moulya, K. P.; Manjunatha, J. G.; Aljuwayid, A. M.; Ataollahi, N.
Application of Poly Dl-Phenylalanine Modified Carbon Nanotube Electrode for Sensitive and Selective Detection of Tinidazole / Moulya, K. P.; Manjunatha, J. G.; Aljuwayid, A. M.; Ataollahi, N.. - In: CHEMISTRYSELECT. - ISSN 2365-6549. - 2024, 9:24(2024), pp. 1-11. [10.1002/slct.202401843]
File in questo prodotto:
File Dimensione Formato  
ChemistrySelect - 2024 - Moulya - Application of Poly Dl‐Phenylalanine Modified Carbon Nanotube Electrode for Sensitive and.pdf

Solo gestori archivio

Descrizione: main article
Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.3 MB
Formato Adobe PDF
2.3 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/421570
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact