The aim of this study was to verify treatment accuracy using virtual surgical planning (VSP) with a mandible-first sequence and strict surgical protocol to determine what surgical and methodological factors might influence outcomes. VSP transfer accuracy was evaluated retrospectively through a modified method involving voxelbased superimposition in patients who had undergone bimaxillary surgery with a mandible-first sequence to correct dentoskeletal deformities. Data analysis showed that the movements planned and those executed were substantially equivalent (p < 0.01), with the exception of mandibular and maxillary sagittal movements that were 0.72 ± 0.90 mm and 1.41 ± 1.04 mm smaller, respectively, than planned. This study showed that a mandible-first sequence is accurate for transferring virtual surgical planning intraoperatively. There are several factors involved in the proper transfer of virtual planning beyond the software, such as surgical technique and sequencing. Inaccurate sagittal movements and maxillary repositioning seem to depend mainly on surgical factors.
Accuracy of virtual surgical planning in bimaxillary orthognathic surgery with mandible first sequence: A retrospective study / Trevisiol, Lorenzo; Bersani, Massimo; Martinez Garza, Alejandro; Alvarado, Esteban; Arnett, G. William; D'Agostino, Antonio. - In: JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY. - ISSN 1010-5182. - 51:5(2023), pp. 280-287. [10.1016/j.jcms.2023.05.015]
Accuracy of virtual surgical planning in bimaxillary orthognathic surgery with mandible first sequence: A retrospective study
Trevisiol, Lorenzo;
2023-01-01
Abstract
The aim of this study was to verify treatment accuracy using virtual surgical planning (VSP) with a mandible-first sequence and strict surgical protocol to determine what surgical and methodological factors might influence outcomes. VSP transfer accuracy was evaluated retrospectively through a modified method involving voxelbased superimposition in patients who had undergone bimaxillary surgery with a mandible-first sequence to correct dentoskeletal deformities. Data analysis showed that the movements planned and those executed were substantially equivalent (p < 0.01), with the exception of mandibular and maxillary sagittal movements that were 0.72 ± 0.90 mm and 1.41 ± 1.04 mm smaller, respectively, than planned. This study showed that a mandible-first sequence is accurate for transferring virtual surgical planning intraoperatively. There are several factors involved in the proper transfer of virtual planning beyond the software, such as surgical technique and sequencing. Inaccurate sagittal movements and maxillary repositioning seem to depend mainly on surgical factors.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione