Objective. To evaluate intra-observer diagnostic reproducibility using traditional slides (TS) versus whole slide images (WSI). Methods. TS and WSI of 1427 prostatic biopsies (107 consecutive patients) were evaluated by a single pathologist. Agreement between readings was evaluated with Gwet’s Agreement coefficient (AC) and Landis and Koch benchmark scale. Results. The positive/negative agreement between the readings was almost perfect (AC1= 0.962; 95% CI[0.949,0.974]), with method independent distribution of discrepancies. Among positive biopsies, 212 had identical Gleason score (GS) on TS and WSI and discordant GS in 69 cases (AC2 = 0.932; 95% CI[0.907, 0.956]). Concordant negative and positive patient classification was observed in 39 and 64 cases, respectively; two cases were assigned to the positive group on TS and 2 on WSI configuring an almost perfect agreement (AC1=0.929; 95% C1[0.860, 0.998]). ISUP Grade group (ISUP GG) agreement was evaluated in the 60 concordantly positive cases: in 45 cases it was identical on TS and WSI; in 10 biopsies the discrepancy implied a modification of the assigned ISUP GG of ≤ 1 class and in 5 the discrepancy implied a modification of 2 classes. Gwet’s agreement coefficient was (95% CI [0.834, 0.962]), i. e.: almost perfect agreement. Conclusions. Our data show almost perfect agreement between digital and traditional diagnostic activity in a routine setting, confirming that digital pathology can be safely introduced into routine workflows.
Diagnostic concordance between traditional and digital workflows. A study on 1427 prostate biopsies / Torresani, Evelin; Gentilini, Maria; Adalgisa, ; Grassi, Stefano; Cima, Luca; Pedrolli, Irene; Cai, Tommaso; Puglisi, Marco; Vattovani, Valentino; Guadin, Bianca; Brunelli, Matteo; Doglioni, Claudio; Barbareschi, Mattia. - In: PATHOLOGICA. - ISSN 1591-951X. - 115:4(2023), pp. 221-226. [10.32074/1591-951X-896]
Diagnostic concordance between traditional and digital workflows. A study on 1427 prostate biopsies
Doglioni, Claudio;Barbareschi, Mattia
2023-01-01
Abstract
Objective. To evaluate intra-observer diagnostic reproducibility using traditional slides (TS) versus whole slide images (WSI). Methods. TS and WSI of 1427 prostatic biopsies (107 consecutive patients) were evaluated by a single pathologist. Agreement between readings was evaluated with Gwet’s Agreement coefficient (AC) and Landis and Koch benchmark scale. Results. The positive/negative agreement between the readings was almost perfect (AC1= 0.962; 95% CI[0.949,0.974]), with method independent distribution of discrepancies. Among positive biopsies, 212 had identical Gleason score (GS) on TS and WSI and discordant GS in 69 cases (AC2 = 0.932; 95% CI[0.907, 0.956]). Concordant negative and positive patient classification was observed in 39 and 64 cases, respectively; two cases were assigned to the positive group on TS and 2 on WSI configuring an almost perfect agreement (AC1=0.929; 95% C1[0.860, 0.998]). ISUP Grade group (ISUP GG) agreement was evaluated in the 60 concordantly positive cases: in 45 cases it was identical on TS and WSI; in 10 biopsies the discrepancy implied a modification of the assigned ISUP GG of ≤ 1 class and in 5 the discrepancy implied a modification of 2 classes. Gwet’s agreement coefficient was (95% CI [0.834, 0.962]), i. e.: almost perfect agreement. Conclusions. Our data show almost perfect agreement between digital and traditional diagnostic activity in a routine setting, confirming that digital pathology can be safely introduced into routine workflows.File | Dimensione | Formato | |
---|---|---|---|
torresani_gentilini_barbareschi_2023_path.pdf
accesso aperto
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Creative commons
Dimensione
252.25 kB
Formato
Adobe PDF
|
252.25 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione