Purpose/Objective: To determine intrafraction prostate motion during volumetric modulated arc therapy (VMAT) using transperineal ultrasound (US) real-time tracking. Methods and Materials: 770 US monitoring sessions in 38 prostate cancer patients' VMAT treatment series were retrospectively evaluated. Intrafraction motion assessment of the prostate was based on continuous position monitoring with a 4-dimensional US system along the 3 directions: left-right (LR), anterior-posterior (AP), and inferior-superior (SI). The overall mean values and standard deviations (SD) along with random and systematic errors were calculated. Results: The mean duration of each monitoring session was 254 s. The mean (μ), the systematic error (Σ), and the random error (σ) of intrafraction prostate displacement were μ = (0.01, −0.08, 0.15) mm, Σ = (0.30, 0.34, 0.23) mm, and σ = (0.59, 0.73, 0.64) mm in the LR, AP and SI directions, respectively. The percentage of treatments for which prostate displacement was ≤2 mm was 97.01%, 92.24%, and 95.77% in the LR, AP, and SI directions, respectively. At 60 s, a vector length of prostate displacement >2 mm was present in 0.67% of the data. The percentage increased to 2.42%, 6.14%, and 9.35% at 120 s, 180 s, and 240 s, respectively. Conclusions: The magnitudes of intrafraction prostate motion along the SI and AP directions were comparable. On average, the smallest motion was in the LR direction and the largest in AP direction. Most of the prostate displacements were within a few millimeters. However, with increasing treatment time (eg, during hypofractionation), larger 3-dimensional prostate displacements up to 18.30 mm could be observed. Shortening treatment time can reduce the impact of intrafraction motion and potentially allows smaller safety margins.

Determination of Intrafraction Prostate Motion During External Beam Radiation Therapy With a Transperineal 4-Dimensional Ultrasound Real-Time Tracking System / Sihono, D.S.K., Ehmann, M., Heitmann, S., von Swietochowski, S., Grimm, M., Boda-Heggemann, J., Lohr, F., Wenz, F., Wertz, H.. - In: INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS. - ISSN 0360-3016. - 101:1(2018), pp. 136-143. [10.1016/j.ijrobp.2018.01.040]

Determination of Intrafraction Prostate Motion During External Beam Radiation Therapy With a Transperineal 4-Dimensional Ultrasound Real-Time Tracking System

Lohr, Frank;
2018-01-01

Abstract

Purpose/Objective: To determine intrafraction prostate motion during volumetric modulated arc therapy (VMAT) using transperineal ultrasound (US) real-time tracking. Methods and Materials: 770 US monitoring sessions in 38 prostate cancer patients' VMAT treatment series were retrospectively evaluated. Intrafraction motion assessment of the prostate was based on continuous position monitoring with a 4-dimensional US system along the 3 directions: left-right (LR), anterior-posterior (AP), and inferior-superior (SI). The overall mean values and standard deviations (SD) along with random and systematic errors were calculated. Results: The mean duration of each monitoring session was 254 s. The mean (μ), the systematic error (Σ), and the random error (σ) of intrafraction prostate displacement were μ = (0.01, −0.08, 0.15) mm, Σ = (0.30, 0.34, 0.23) mm, and σ = (0.59, 0.73, 0.64) mm in the LR, AP and SI directions, respectively. The percentage of treatments for which prostate displacement was ≤2 mm was 97.01%, 92.24%, and 95.77% in the LR, AP, and SI directions, respectively. At 60 s, a vector length of prostate displacement >2 mm was present in 0.67% of the data. The percentage increased to 2.42%, 6.14%, and 9.35% at 120 s, 180 s, and 240 s, respectively. Conclusions: The magnitudes of intrafraction prostate motion along the SI and AP directions were comparable. On average, the smallest motion was in the LR direction and the largest in AP direction. Most of the prostate displacements were within a few millimeters. However, with increasing treatment time (eg, during hypofractionation), larger 3-dimensional prostate displacements up to 18.30 mm could be observed. Shortening treatment time can reduce the impact of intrafraction motion and potentially allows smaller safety margins.
2018
1
Sihono, Dwi Seno Kuncoro; Ehmann, Michael; Heitmann, Sigrun; von Swietochowski, Sandra; Grimm, Mario; Boda-Heggemann, Judit; Lohr, Frank; Wenz, Freder...espandi
Determination of Intrafraction Prostate Motion During External Beam Radiation Therapy With a Transperineal 4-Dimensional Ultrasound Real-Time Tracking System / Sihono, D.S.K., Ehmann, M., Heitmann, S., von Swietochowski, S., Grimm, M., Boda-Heggemann, J., Lohr, F., Wenz, F., Wertz, H.. - In: INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS. - ISSN 0360-3016. - 101:1(2018), pp. 136-143. [10.1016/j.ijrobp.2018.01.040]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/403131
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 41
  • OpenAlex 46
social impact