Laser scanning-based patient surface positioning and surveillance may complement image-guided radiotherapy (IGRT) as a nonradiation-based approach. We investigated the performance of an optical system compared to standard kilovoltage cone-beam computed tomography (CBCT) and its potential to reduce the number of daily CBCTs. We analyzed the patient positioning of 153 treatment fractions in 21 patients applied to three different treatment regions. Patients were first scanned with CBCT, shifted to the optimal isocenter position, and an optical scan was performed to verify the matching in relation to CBCT. For the head-and-neck region, the lateral/longitudinal/vertical/rotational/roll and pitch shift was 0.9 +/- 1.8 mm/-2.7 +/- 3.8 mm/-0.8 +/- 3.6 mm/0.0 +/- 1.1A degrees/-0.5 +/- 2.1A degrees/0.2 +/- 1.6A degrees. For the thorax, the lateral/longitudinal/vertical/roll and pitch shift was -1.2 +/- 3.6 mm/0.8 +/- 5.1 mm/0.8 +/- 4.3 mm/0.6 +/- 1.4A degrees/0.1 +/- 0.9A degrees/0.3 +/- 1.0A degrees. For the pelvis, the respective values were -2.5 +/- 4.1 mm/4.6 +/- 7.3 mm/-5.1 +/- 7.4 mm/0.3 +/- 1.1A degrees/-0.5 +/- 1.0A degrees/0.3 +/- 2.1A degrees. In total, the recorded disagreement was -1.0 +/- 3.6 mm/1.0 +/- 6.3 mm/-1.8 +/- 5.9 mm/0.3 +/- 1.2A degrees/-0.3 +/- 1.5A degrees/0.2 +/- 1.7A degrees. This analysis showed good agreement between the optical scanner approach and CBCT. The optical system holds potential to ensure precise patient positioning and reduced CBCT frequency in tumor locations with fixed relation to surface structures.

Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy / Stieler, F., Wenz, F., Scherrer, D., Bernhardt, M., Lohr, F.. - In: STRAHLENTHERAPIE UND ONKOLOGIE. - ISSN 0179-7158. - 188:12(2012), pp. 1080-1084. [10.1007/s00066-012-0244-7]

Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy

Lohr F
2012-01-01

Abstract

Laser scanning-based patient surface positioning and surveillance may complement image-guided radiotherapy (IGRT) as a nonradiation-based approach. We investigated the performance of an optical system compared to standard kilovoltage cone-beam computed tomography (CBCT) and its potential to reduce the number of daily CBCTs. We analyzed the patient positioning of 153 treatment fractions in 21 patients applied to three different treatment regions. Patients were first scanned with CBCT, shifted to the optimal isocenter position, and an optical scan was performed to verify the matching in relation to CBCT. For the head-and-neck region, the lateral/longitudinal/vertical/rotational/roll and pitch shift was 0.9 +/- 1.8 mm/-2.7 +/- 3.8 mm/-0.8 +/- 3.6 mm/0.0 +/- 1.1A degrees/-0.5 +/- 2.1A degrees/0.2 +/- 1.6A degrees. For the thorax, the lateral/longitudinal/vertical/roll and pitch shift was -1.2 +/- 3.6 mm/0.8 +/- 5.1 mm/0.8 +/- 4.3 mm/0.6 +/- 1.4A degrees/0.1 +/- 0.9A degrees/0.3 +/- 1.0A degrees. For the pelvis, the respective values were -2.5 +/- 4.1 mm/4.6 +/- 7.3 mm/-5.1 +/- 7.4 mm/0.3 +/- 1.1A degrees/-0.5 +/- 1.0A degrees/0.3 +/- 2.1A degrees. In total, the recorded disagreement was -1.0 +/- 3.6 mm/1.0 +/- 6.3 mm/-1.8 +/- 5.9 mm/0.3 +/- 1.2A degrees/-0.3 +/- 1.5A degrees/0.2 +/- 1.7A degrees. This analysis showed good agreement between the optical scanner approach and CBCT. The optical system holds potential to ensure precise patient positioning and reduced CBCT frequency in tumor locations with fixed relation to surface structures.
2012
12
Stieler, F; Wenz, F; Scherrer, D; Bernhardt, M; Lohr, F
Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy / Stieler, F., Wenz, F., Scherrer, D., Bernhardt, M., Lohr, F.. - In: STRAHLENTHERAPIE UND ONKOLOGIE. - ISSN 0179-7158. - 188:12(2012), pp. 1080-1084. [10.1007/s00066-012-0244-7]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/403088
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
  • OpenAlex 25
social impact