The precast prestressed efficiently fabricated frame (PPEFF) represents a rapid assembly system. However, it may possess limited energy-dissipating capacity when applied to high-rise buildings in high seismic-prone zones. To solve this problem, a precast prestressed efficiently fabricated frame with shear panel dampers (PPEFF-SPDs) is proposed in this paper. Along this vein, this study focuses on the effective modular techniques for damper installation as well as the seismic performance of a PPEFF-SPDs. To investigate the seismic performance of the PPEFF-SPDs, a 0.8scale two-story specimen was tested using hybrid and quasi-static tests. The test results showed that the PPEFF-SPDs designed according to Chinese building codes exhibited reliable seismic performance with the corresponding performance objectives satisfied. The specimen displayed an effective and stable energy-dissipating capacity even when the inter-story drift ratios reached 2%, and the specimen damage conformed to the failure pattern foreseen for strong columns and weak beams. This study demonstrates the feasibility of the proposed PPEFF-SPDs and provides a promising alternative for the PPEFF in high seismic-prone zones.
Experimental Performance and Numerical Prediction of Precast Prestressed Concrete Frames Endowed with Shear Panel Dampers / Yang, Sp; Wu, B; Wang, Sz; Yang, G; Wang, Z; Xu, Gs; Guo, Hs; Li, Lm; Bursi, Os. - In: JOURNAL OF BUILDING ENGINEERING. - ISSN 2352-7102. - 2023, 77:107461(2023), pp. 1-24. [10.1016/j.jobe.2023.107461]
Experimental Performance and Numerical Prediction of Precast Prestressed Concrete Frames Endowed with Shear Panel Dampers
Wang, Z;Bursi, OS
2023-01-01
Abstract
The precast prestressed efficiently fabricated frame (PPEFF) represents a rapid assembly system. However, it may possess limited energy-dissipating capacity when applied to high-rise buildings in high seismic-prone zones. To solve this problem, a precast prestressed efficiently fabricated frame with shear panel dampers (PPEFF-SPDs) is proposed in this paper. Along this vein, this study focuses on the effective modular techniques for damper installation as well as the seismic performance of a PPEFF-SPDs. To investigate the seismic performance of the PPEFF-SPDs, a 0.8scale two-story specimen was tested using hybrid and quasi-static tests. The test results showed that the PPEFF-SPDs designed according to Chinese building codes exhibited reliable seismic performance with the corresponding performance objectives satisfied. The specimen displayed an effective and stable energy-dissipating capacity even when the inter-story drift ratios reached 2%, and the specimen damage conformed to the failure pattern foreseen for strong columns and weak beams. This study demonstrates the feasibility of the proposed PPEFF-SPDs and provides a promising alternative for the PPEFF in high seismic-prone zones.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S2352710223016418-main_compressed (1).pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.44 MB
Formato
Adobe PDF
|
1.44 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione