The results of experimental tests conducted on the joints of a wood-based prefabricated sandwich panel recently developed in Norway are presented. The connections investigated were those involved in constituting the lateral-force-resisting system for a wall assembly, namely the panel-to-sill connections. Several European standards are undergoing a revision process, one of which describes the procedures and methods of assessment of timber joints made with mechanical fasteners, tested under quasi-static cyclic conditions. The objective of this investigation was therefore to compare the current methodologies with those presented in a revision proposal and a third method used in Japan. The revision proposal introduces the concept of strength degradation, which should ensure a large amount of energy dissipation without significant loss of strength when designing structures for earthquake loads. The results of the testing regime are presented and the advantages and disadvantages of the three methods are discussed.

Assessment of ductility properties of the connections in a prefabricated timber panel / Pasca, D. P.; Myrvhold, C. A.; Hoibo, O. A.; Nyrud, A. Q.; Tomasi, R.. - In: PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS. STRUCTURES AND BUILDINGS. - ISSN 0965-0911. - 173:12(2020), pp. 939-947. [10.1680/jstbu.19.00112]

Assessment of ductility properties of the connections in a prefabricated timber panel

Tomasi R.
2020-01-01

Abstract

The results of experimental tests conducted on the joints of a wood-based prefabricated sandwich panel recently developed in Norway are presented. The connections investigated were those involved in constituting the lateral-force-resisting system for a wall assembly, namely the panel-to-sill connections. Several European standards are undergoing a revision process, one of which describes the procedures and methods of assessment of timber joints made with mechanical fasteners, tested under quasi-static cyclic conditions. The objective of this investigation was therefore to compare the current methodologies with those presented in a revision proposal and a third method used in Japan. The revision proposal introduces the concept of strength degradation, which should ensure a large amount of energy dissipation without significant loss of strength when designing structures for earthquake loads. The results of the testing regime are presented and the advantages and disadvantages of the three methods are discussed.
2020
12
Pasca, D. P.; Myrvhold, C. A.; Hoibo, O. A.; Nyrud, A. Q.; Tomasi, R.
Assessment of ductility properties of the connections in a prefabricated timber panel / Pasca, D. P.; Myrvhold, C. A.; Hoibo, O. A.; Nyrud, A. Q.; Tomasi, R.. - In: PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS. STRUCTURES AND BUILDINGS. - ISSN 0965-0911. - 173:12(2020), pp. 939-947. [10.1680/jstbu.19.00112]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/377470
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex ND
social impact