KAGRA is a second-generation interferometric gravitational-wave detector with 3 km arms constructed at Kamioka, Gifu, Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which reduces seismic motion at low frequencies and increases the stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April–May 2018, we operated a 3 km Michelson interferometer with a cryogenic
test mass for 10 d, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this ‘bKAGRA Phase 1’ operation. We have demonstrated the feasibility of 3 km interferometer alignment and control with cryogenic mirrors.
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA / Akutsu, T; Ando, M; Arai, K; Arai, Y; Araki, S; Araya, A; Aritomi, N; Asada, H; Aso, Y; Atsuta, S; Awai, K; Bae, S; Baiotti, L; A Barton, M; Cannon, K; Capocasa, E; Chen, C-S; Chiu, T-W; Cho, K; Chu, Y-K; Craig, K; Creus, W; Doi, K; Eda, K; Enomoto, Y; Flaminio, R; Fujii, Y; Fujimoto, M-K; Fukunaga, M; Fukushima, M; Furuhata, T; Hagiwara, A; Haino, S; Hasegawa, K; Hashino, K; Hayama, K; Hirobayashi, S; Hirose, E; H Hsieh, B; Huang, C-Z; Ikenoue, B; Inoue, Y; Ioka, K; Itoh, Y; Izumi, K; Kaji, T; Kajita, T; Kakizaki, M; Kamiizumi, M; Kanbara, S; Kanda, N; Kanemura, S; Kaneyama, M; Kang, G; Kasuya, J; Kataoka, Y; Kawai, N; Kawamura, S; Kawasaki, T; Kim, C; Kim, J; C Kim, J; S Kim, W; Kim, Y-M; Kimura, N; Kinugawa, T; Kirii, S; Kitaoka, Y; Kitazawa, H; Kojima, Y; Kokeyama, K; Komori, K; H Kong, A K; Kotake, K; Kozu, R; Kumar, R; Kuo, H-S; Kuroyanagi, S; K Lee, H; M Lee, H; W Lee, H; Leonardi, M; Lin, C-Y; Lin, F-L; C Liu, G; Liu, Y; Majorana, E; Mano, S; Marchio, M; Matsui, T; Matsushima, F; Michimura, Y; Mio, N; Miyakawa, O; Miyamoto, A; Miyamoto, T; Miyo, K; Miyoki, S; Morii, W; Morisaki, S; Moriwaki, Y; Morozumi, T; Murakami, I; Musha, M; Nagano, K; Nagano, S; Nakamura, K; Nakamura, T; Nakano, H; Nakano, M; Nakao, K; Namai, Y; Narikawa, T; Naticchioni, L; Nguyen Quynh, L; Ni, W-T; Nishizawa, A; Obuchi, Y; Ochi, T; J Oh, J; H Oh, S; Ohashi, M; Ohishi, N; Ohkawa, M; Okutomi, K; Ono, K; Oohara, K; P Ooi, C; Pan, S-S; Park, J; E Peña Arellano, F; Pinto, I; Sago, N; Saijo, M; Saito, Y; Saitou, S; Sakai, K; Sakai, Y; Sakai, Y; Sasai, M; Sasaki, M; Sasaki, Y; Sato, N; Sato, S; Sato, T; Sekiguchi, Y; Seto, N; Shibata, M; Shimoda, T; Shinkai, H; Shishido, T; Shoda, A; Somiya, K; J Son, E; Suemasa, A; Suzuki, T; Suzuki, T; Tagoshi, H; Tahara, H; Takahashi, H; Takahashi, R; Takamori, A; Takeda, H; Tanaka, H; Tanaka, K; Tanaka, T; Tanioka, S; N Tapia San Martin, E; Tatsumi, D; Terashima, S; Tomaru, T; Tomura, T; Travasso, F; Tsubono, K; Tsuchida, S; Uchikata, N; Uchiyama, T; Ueda, A; Uehara, T; Ueki, S; Ueno, K; Uraguchi, F; Ushiba, T; M van Putten, M H P; Vocca, H; Wada, S; Wakamatsu, T; Watanabe, Y; Xu, W-R; Yamada, T; Yamamoto, A; Yamamoto, K; Yamamoto, K; Yamamoto, S; Yamamoto, T; Yokogawa, K; Yokoyama, J; Yokozawa, T; H Yoon, T; Yoshioka, T; Yuzurihara, H; Zeidler, S; Zhu, Z-H. - In: CLASSICAL AND QUANTUM GRAVITY. - ISSN 0264-9381. - 36:16(2019), p. 165008. [10.1088/1361-6382/ab28a9]
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
KAGRA is a second-generation interferometric gravitational-wave detector with 3 km arms constructed at Kamioka, Gifu, Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which reduces seismic motion at low frequencies and increases the stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April–May 2018, we operated a 3 km Michelson interferometer with a cryogenic
test mass for 10 d, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this ‘bKAGRA Phase 1’ operation. We have demonstrated the feasibility of 3 km interferometer alignment and control with cryogenic mirrors.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/370468
Citazioni
ND
39
40
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.