Background: Pathophysiological features of coronavirus disease 2019-associated acute respiratory distress syndrome (COVID-19 ARDS) were indicated to be somewhat different from those described in nonCOVID-19 ARDS, because of relatively preserved compliance of the respiratory system despite marked hypoxemia. We aim ascertaining whether respiratory system static compliance (Crs), driving pressure (DP), and tidal volume normalized for ideal body weight (VT/kg IBW) at the 1st day of controlled mechanical ventilation are associated with intensive care unit (ICU) mortality in COVID-19 ARDS. Methods: Observational multicenter cohort study. All consecutive COVID-19 adult patients admitted to 25 ICUs belonging to the COVID-19 VENETO ICU network (February 28th-April 28th, 2020), who received controlled mechanical ventilation, were screened. Only patients fulfilling ARDS criteria and with complete records of Crs, DP and VT/kg IBW within the 1st day of controlled mechanical ventilation were included. Crs, DP and VT/kg IBW were collected in sedated, paralyzed and supine patients. Results: A total of 704 COVID-19 patients were screened and 241 enrolled. Seventy-one patients (29%) died in ICU. The logistic regression analysis showed that: (1) Crs was not linearly associated with ICU mortality (p value for nonlinearity = 0.01), with a greater risk of death for values < 48 ml/cmH2O; (2) the association between DP and ICU mortality was linear (p value for nonlinearity = 0.68), and increasing DP from 10 to 14 cmH2O caused significant higher odds of in-ICU death (OR 1.45, 95% CI 1.06-1.99); (3) VT/kg IBW was not associated with a significant increase of the risk of death (OR 0.92, 95% CI 0.55-1.52). Multivariable analysis confirmed these findings. Conclusions: Crs < 48 ml/cmH2O was associated with ICU mortality, while DP was linearly associated with mortality. DP should be kept as low as possible, even in the case of relatively preserved Crs, irrespective of VT/kg IBW, to reduce the risk of death.

Static compliance and driving pressure are associated with ICU mortality in intubated COVID-19 ARDS / Boscolo, Annalisa; Sella, Nicolò; Lorenzoni, Giulia; Pettenuzzo, Tommaso; Pasin, Laura; Pretto, Chiara; Tocco, Martina; Tamburini, Enrico; De Cassai, Alessandro; Rosi, Paolo; Polati, Enrico; Donadello, Katia; Gottin, Leonardo; De Rosa, Silvia; Baratto, Fabio; Toffoletto, Fabio; Ranieri, V Marco; Gregori, Dario; Navalesi, Paolo. - In: CRITICAL CARE. - ISSN 1466-609X. - 25:1(2021), pp. 2631-2638. [10.1186/s13054-021-03667-6]

Static compliance and driving pressure are associated with ICU mortality in intubated COVID-19 ARDS

Donadello, Katia;De Rosa, Silvia;
2021-01-01

Abstract

Background: Pathophysiological features of coronavirus disease 2019-associated acute respiratory distress syndrome (COVID-19 ARDS) were indicated to be somewhat different from those described in nonCOVID-19 ARDS, because of relatively preserved compliance of the respiratory system despite marked hypoxemia. We aim ascertaining whether respiratory system static compliance (Crs), driving pressure (DP), and tidal volume normalized for ideal body weight (VT/kg IBW) at the 1st day of controlled mechanical ventilation are associated with intensive care unit (ICU) mortality in COVID-19 ARDS. Methods: Observational multicenter cohort study. All consecutive COVID-19 adult patients admitted to 25 ICUs belonging to the COVID-19 VENETO ICU network (February 28th-April 28th, 2020), who received controlled mechanical ventilation, were screened. Only patients fulfilling ARDS criteria and with complete records of Crs, DP and VT/kg IBW within the 1st day of controlled mechanical ventilation were included. Crs, DP and VT/kg IBW were collected in sedated, paralyzed and supine patients. Results: A total of 704 COVID-19 patients were screened and 241 enrolled. Seventy-one patients (29%) died in ICU. The logistic regression analysis showed that: (1) Crs was not linearly associated with ICU mortality (p value for nonlinearity = 0.01), with a greater risk of death for values < 48 ml/cmH2O; (2) the association between DP and ICU mortality was linear (p value for nonlinearity = 0.68), and increasing DP from 10 to 14 cmH2O caused significant higher odds of in-ICU death (OR 1.45, 95% CI 1.06-1.99); (3) VT/kg IBW was not associated with a significant increase of the risk of death (OR 0.92, 95% CI 0.55-1.52). Multivariable analysis confirmed these findings. Conclusions: Crs < 48 ml/cmH2O was associated with ICU mortality, while DP was linearly associated with mortality. DP should be kept as low as possible, even in the case of relatively preserved Crs, irrespective of VT/kg IBW, to reduce the risk of death.
2021
1
Boscolo, Annalisa; Sella, Nicolò; Lorenzoni, Giulia; Pettenuzzo, Tommaso; Pasin, Laura; Pretto, Chiara; Tocco, Martina; Tamburini, Enrico; De Cassai, ...espandi
Static compliance and driving pressure are associated with ICU mortality in intubated COVID-19 ARDS / Boscolo, Annalisa; Sella, Nicolò; Lorenzoni, Giulia; Pettenuzzo, Tommaso; Pasin, Laura; Pretto, Chiara; Tocco, Martina; Tamburini, Enrico; De Cassai, Alessandro; Rosi, Paolo; Polati, Enrico; Donadello, Katia; Gottin, Leonardo; De Rosa, Silvia; Baratto, Fabio; Toffoletto, Fabio; Ranieri, V Marco; Gregori, Dario; Navalesi, Paolo. - In: CRITICAL CARE. - ISSN 1466-609X. - 25:1(2021), pp. 2631-2638. [10.1186/s13054-021-03667-6]
File in questo prodotto:
File Dimensione Formato  
boscolo_sella_derosa_2021_crcare.pdf

accesso aperto

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Creative commons
Dimensione 941.49 kB
Formato Adobe PDF
941.49 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/364426
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 19
  • OpenAlex ND
social impact