Introduction: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. Methods: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. Results: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (β = -0.64; p = 0.02) and heart rate (β = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (β = 0.35; p < 0.001; β = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (β = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (β = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and β2-microglobulin were similar across modalities. β2-Microglobulin removal efficacy was greater in the EMiC®2 group (β = 0-2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. Discussion: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.

Clinical Assessment of Continuous Hemodialysis with the Medium Cutoff EMiC®2 Membrane in Patients with Septic Shock / Ferrari, Fiorenza; Husain-Syed, Faeq; Milla, Paola; Lorenzin, Anna; Scudeller, Luigia; Sartori, Marco; Gramaticopolo, Silvia; D'Auria, Luigi; Guglielmi, Angelo; Cornara, Pietro; De Rosa, Silvia; Zanella, Monica; Corradi, Valentina; De Cal, Massimo; Danzi, Vinicio; Giavarina, Davide; Brendolan, Alessandra; Mojoli, Francesco; Arpicco, Silvia; Ronco, Claudio. - In: BLOOD PURIFICATION. - ISSN 0253-5068. - 51:11(2022), pp. 912-922. [10.1159/000522321]

Clinical Assessment of Continuous Hemodialysis with the Medium Cutoff EMiC®2 Membrane in Patients with Septic Shock

De Rosa, Silvia;
2022-01-01

Abstract

Introduction: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. Methods: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. Results: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (β = -0.64; p = 0.02) and heart rate (β = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (β = 0.35; p < 0.001; β = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (β = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (β = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and β2-microglobulin were similar across modalities. β2-Microglobulin removal efficacy was greater in the EMiC®2 group (β = 0-2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. Discussion: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.
2022
11
Ferrari, Fiorenza; Husain-Syed, Faeq; Milla, Paola; Lorenzin, Anna; Scudeller, Luigia; Sartori, Marco; Gramaticopolo, Silvia; D'Auria, Luigi; Guglielm...espandi
Clinical Assessment of Continuous Hemodialysis with the Medium Cutoff EMiC®2 Membrane in Patients with Septic Shock / Ferrari, Fiorenza; Husain-Syed, Faeq; Milla, Paola; Lorenzin, Anna; Scudeller, Luigia; Sartori, Marco; Gramaticopolo, Silvia; D'Auria, Luigi; Guglielmi, Angelo; Cornara, Pietro; De Rosa, Silvia; Zanella, Monica; Corradi, Valentina; De Cal, Massimo; Danzi, Vinicio; Giavarina, Davide; Brendolan, Alessandra; Mojoli, Francesco; Arpicco, Silvia; Ronco, Claudio. - In: BLOOD PURIFICATION. - ISSN 0253-5068. - 51:11(2022), pp. 912-922. [10.1159/000522321]
File in questo prodotto:
File Dimensione Formato  
EMIC2.pdf

Solo gestori archivio

Descrizione: first online
Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 420.43 kB
Formato Adobe PDF
420.43 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/363764
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact