An approach based on a stochastic optimization technique is proposed for medical microwave imaging. The approach is based on the integral equations of the electromagnetic inverse scattering. After discretization of the continuous model, the problem solution is recast as a global optimization problem. A functional is costructed on the basis of a Markov random field model and minimized by a genetic algorithm. In order to reduce the computational load, a model of the cross section of the biological body is considered. In this way, the investigation area is limited by separating the scattering contribution of a fixed region under test from those of other parts of the model. Some preliminary results concerning a two-dimensional model of a human thorax are reported. Such a biological structure is inspected by the proposed tomographic approach in order to detect and localize the presence of and object" modeling a tumor."

Microwave Medical Imaging: Potentialities and Limitations of a Stochastic Optimization Technique / Massa, Andrea; Pastorino, Matteo; Rosani, Andrea; Caorsi, Salvatore. - ELETTRONICO. - (2004).

Microwave Medical Imaging: Potentialities and Limitations of a Stochastic Optimization Technique

Massa, Andrea;Rosani, Andrea;
2004-01-01

Abstract

An approach based on a stochastic optimization technique is proposed for medical microwave imaging. The approach is based on the integral equations of the electromagnetic inverse scattering. After discretization of the continuous model, the problem solution is recast as a global optimization problem. A functional is costructed on the basis of a Markov random field model and minimized by a genetic algorithm. In order to reduce the computational load, a model of the cross section of the biological body is considered. In this way, the investigation area is limited by separating the scattering contribution of a fixed region under test from those of other parts of the model. Some preliminary results concerning a two-dimensional model of a human thorax are reported. Such a biological structure is inspected by the proposed tomographic approach in order to detect and localize the presence of and object" modeling a tumor."
2004
Trento, Italia
Università degli Studi di Trento. DEPARTMENT OF INFORMATION AND COMMUNICATION TECHNOLOGY
Microwave Medical Imaging: Potentialities and Limitations of a Stochastic Optimization Technique / Massa, Andrea; Pastorino, Matteo; Rosani, Andrea; Caorsi, Salvatore. - ELETTRONICO. - (2004).
Massa, Andrea; Pastorino, Matteo; Rosani, Andrea; Caorsi, Salvatore
File in questo prodotto:
File Dimensione Formato  
DIT-04-079.pdf

accesso aperto

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 779.87 kB
Formato Adobe PDF
779.87 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/359072
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact