Recently developed detectors can deliver high resolution and high contrast images of nanostructured carbon based materials in low voltage scanning electron microscopes (LVSEM) with beam deceleration. Monte Carlo Simulations are also used to predict under which exact imaging conditions purely compositional contrast can be obtained and optimised. This allows the prediction of the electron signal intensity in angle selective conditions for back-scattered electron (BSE) imaging in LVSEM and compares it to experimental signals. Angle selective detection with a concentric back scattered (CBS) detector is considered in the model in the absence and presence of a deceleration field, respectively. The validity of the model prediction for both cases was tested experimentally for amorphous C and Cu and applied to complex nanostructured carbon based materials, namely a Poly(N-isopropylacrylamide)/Poly(ethylene glycol) Diacrylate (PNIPAM/PEGDA) semi-interpenetration network (IPN) and a Poly(3-hexylthiophene-2,5-diyl) (P3HT) film, to map nano-scale composition and crystallinity distribution by avoiding experimental imaging conditions that lead to a mixed topographical and compositional contrast

Angle selective backscattered electron contrast in the low-voltage scanning electron microscope: Simulation and experiment for polymers / Wan, Q.; Masters, R. C.; Lidzey, D.; Abrams, K. J.; Dapor, M.; Plenderleith, R. A.; Rimmer, S.; Claeyssens, F.; Rodenburg, C.. - In: ULTRAMICROSCOPY. - ISSN 0304-3991. - 171:(2016), pp. 126-138. [10.1016/j.ultramic.2016.09.006]

Angle selective backscattered electron contrast in the low-voltage scanning electron microscope: Simulation and experiment for polymers

Dapor M.;
2016-01-01

Abstract

Recently developed detectors can deliver high resolution and high contrast images of nanostructured carbon based materials in low voltage scanning electron microscopes (LVSEM) with beam deceleration. Monte Carlo Simulations are also used to predict under which exact imaging conditions purely compositional contrast can be obtained and optimised. This allows the prediction of the electron signal intensity in angle selective conditions for back-scattered electron (BSE) imaging in LVSEM and compares it to experimental signals. Angle selective detection with a concentric back scattered (CBS) detector is considered in the model in the absence and presence of a deceleration field, respectively. The validity of the model prediction for both cases was tested experimentally for amorphous C and Cu and applied to complex nanostructured carbon based materials, namely a Poly(N-isopropylacrylamide)/Poly(ethylene glycol) Diacrylate (PNIPAM/PEGDA) semi-interpenetration network (IPN) and a Poly(3-hexylthiophene-2,5-diyl) (P3HT) film, to map nano-scale composition and crystallinity distribution by avoiding experimental imaging conditions that lead to a mixed topographical and compositional contrast
2016
Wan, Q.; Masters, R. C.; Lidzey, D.; Abrams, K. J.; Dapor, M.; Plenderleith, R. A.; Rimmer, S.; Claeyssens, F.; Rodenburg, C.
Angle selective backscattered electron contrast in the low-voltage scanning electron microscope: Simulation and experiment for polymers / Wan, Q.; Masters, R. C.; Lidzey, D.; Abrams, K. J.; Dapor, M.; Plenderleith, R. A.; Rimmer, S.; Claeyssens, F.; Rodenburg, C.. - In: ULTRAMICROSCOPY. - ISSN 0304-3991. - 171:(2016), pp. 126-138. [10.1016/j.ultramic.2016.09.006]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/325752
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 12
social impact