Purpose We investigate the possibility to improve the accuracy of the lateral dose profile for 4He beams with a novel approach, by extending an already validated model for proton beams to heavier ions. Methods The full Molière theory for the Coulomb multiple scattering is applied to the case of 4He beams, with a complete separation of the electromagnetic and of the nuclear contributions in the calculation of the total dose. The latter is described with only three free parameters. Results The accuracy of the results compared with Monte Carlo predictions already validated with experimental data is comparable with other studies at low energy, but improves by a factor 2 at high energy. In addition the found solution is more stable with respect to (multi-) Gaussian and other parameterizations. This result makes this method of interest for applications to Treatment Planning Systems (TPS) in ion beam therapy. Conclusions We propose a model, named MONETα (MOdel of ioN dosE for Therapy for α), for the calculation of the lateral dose of 4He beams in water that allows fast and accurate dose calculations by requiring a small data base of parameters as input.

On the lateral dose profile of 4He beams in water / Embriaco, A.; Bellinzona, V. E.; Fontana, A.; Rotondi, A.. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 40:(2017), pp. 51-58. [10.1016/j.ejmp.2017.07.007]

On the lateral dose profile of 4He beams in water

Bellinzona V. E.;Rotondi A.
2017-01-01

Abstract

Purpose We investigate the possibility to improve the accuracy of the lateral dose profile for 4He beams with a novel approach, by extending an already validated model for proton beams to heavier ions. Methods The full Molière theory for the Coulomb multiple scattering is applied to the case of 4He beams, with a complete separation of the electromagnetic and of the nuclear contributions in the calculation of the total dose. The latter is described with only three free parameters. Results The accuracy of the results compared with Monte Carlo predictions already validated with experimental data is comparable with other studies at low energy, but improves by a factor 2 at high energy. In addition the found solution is more stable with respect to (multi-) Gaussian and other parameterizations. This result makes this method of interest for applications to Treatment Planning Systems (TPS) in ion beam therapy. Conclusions We propose a model, named MONETα (MOdel of ioN dosE for Therapy for α), for the calculation of the lateral dose of 4He beams in water that allows fast and accurate dose calculations by requiring a small data base of parameters as input.
2017
Embriaco, A.; Bellinzona, V. E.; Fontana, A.; Rotondi, A.
On the lateral dose profile of 4He beams in water / Embriaco, A.; Bellinzona, V. E.; Fontana, A.; Rotondi, A.. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 40:(2017), pp. 51-58. [10.1016/j.ejmp.2017.07.007]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/320083
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact