Cardiac surgery is one of the most complex specialties in medicine, akin to a complex sociotechnical system. Patient outcomes are vulnerable to surgical flow disruptions (SFDs), a source of preventable harm. Healthcare providers’ (HCPs) sympathetic activation secondary to emotional states represent an underappreciated source of SFDs. This study’s objective was to demonstrate the feasibility of detecting elevated sympathetic nervous system (SNS) activity as a proxy for emotional distress associated with a medication error using heart rate variability (HRV) analysis. After obtaining informed consent, audio/video and HRV data were captured intraoperatively during cardiac surgery from multiple HCPs. Following a critical medication administration error by the anesthesiologist in-training, the attending anesthesiologists’ recorded HRV data was analyzed using pyphysio, an open-source signal analysis package, to identify events precipitating this near-miss event. We considered elevated low-frequency/high-frequency (LF/HF) HRV ratio (normal value <2) as a primary indicator of SNS activity and emotional distress. A heightened SNS response by the attending anesthesiologist, observed as an LF/HF ratio value of 3.39, was detected prior to the near-miss event. The attending anesthesiologist confirmed a state of significant SNS activity/distress induced by task-irrelevant environmental factors, which led to a temporarily ineffective mental model. Qualitative analysis of audio/video recordings revealed that SNS activation coincided with an argument over operating room management causing SFD. This preliminary study confirms the feasibility of recognizing potentially detrimental psychophysiological states during cardiac surgery in the wild using HRV analysis. To our knowledge, this is the first case demonstrating SNS activation coinciding with self-reported and observable emotional distress during live surgery using HRV. Irrespective of the HCP’s expertise, transient but intense emotional changes may disrupt attention processes leading to SFDs and preventable errors. This work supports the possibility to detect real-time SNS activation, which could enable interventions to proactively mitigate errors. Additional studies on our large database of surgical cases are underway to confirm this observation.

Feasibility of Healthcare Providers’ Autonomic Activation Recognition in Real-Life Cardiac Surgery Using Noninvasive Sensors / Kennedy-Metz, L. R.; Bizzego, A.; Dias, R. D.; Furlanello, C.; Esposito, G.; Zenati, M. A.. - 1293:(2020), pp. 402-408. (Intervento presentato al convegno 22nd International Conference on Human-Computer Interaction, HCI International 2020 tenutosi a Danimarca nel 2020) [10.1007/978-3-030-60700-5_51].

Feasibility of Healthcare Providers’ Autonomic Activation Recognition in Real-Life Cardiac Surgery Using Noninvasive Sensors

Bizzego A.;Furlanello C.;Esposito G.;
2020-01-01

Abstract

Cardiac surgery is one of the most complex specialties in medicine, akin to a complex sociotechnical system. Patient outcomes are vulnerable to surgical flow disruptions (SFDs), a source of preventable harm. Healthcare providers’ (HCPs) sympathetic activation secondary to emotional states represent an underappreciated source of SFDs. This study’s objective was to demonstrate the feasibility of detecting elevated sympathetic nervous system (SNS) activity as a proxy for emotional distress associated with a medication error using heart rate variability (HRV) analysis. After obtaining informed consent, audio/video and HRV data were captured intraoperatively during cardiac surgery from multiple HCPs. Following a critical medication administration error by the anesthesiologist in-training, the attending anesthesiologists’ recorded HRV data was analyzed using pyphysio, an open-source signal analysis package, to identify events precipitating this near-miss event. We considered elevated low-frequency/high-frequency (LF/HF) HRV ratio (normal value <2) as a primary indicator of SNS activity and emotional distress. A heightened SNS response by the attending anesthesiologist, observed as an LF/HF ratio value of 3.39, was detected prior to the near-miss event. The attending anesthesiologist confirmed a state of significant SNS activity/distress induced by task-irrelevant environmental factors, which led to a temporarily ineffective mental model. Qualitative analysis of audio/video recordings revealed that SNS activation coincided with an argument over operating room management causing SFD. This preliminary study confirms the feasibility of recognizing potentially detrimental psychophysiological states during cardiac surgery in the wild using HRV analysis. To our knowledge, this is the first case demonstrating SNS activation coinciding with self-reported and observable emotional distress during live surgery using HRV. Irrespective of the HCP’s expertise, transient but intense emotional changes may disrupt attention processes leading to SFDs and preventable errors. This work supports the possibility to detect real-time SNS activation, which could enable interventions to proactively mitigate errors. Additional studies on our large database of surgical cases are underway to confirm this observation.
2020
Communications in Computer and Information Science
Cham
Springer Science and Business Media Deutschland GmbH
978-3-030-60699-2
978-3-030-60700-5
Feasibility of Healthcare Providers’ Autonomic Activation Recognition in Real-Life Cardiac Surgery Using Noninvasive Sensors / Kennedy-Metz, L. R.; Bizzego, A.; Dias, R. D.; Furlanello, C.; Esposito, G.; Zenati, M. A.. - 1293:(2020), pp. 402-408. (Intervento presentato al convegno 22nd International Conference on Human-Computer Interaction, HCI International 2020 tenutosi a Danimarca nel 2020) [10.1007/978-3-030-60700-5_51].
Kennedy-Metz, L. R.; Bizzego, A.; Dias, R. D.; Furlanello, C.; Esposito, G.; Zenati, M. A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/319238
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact