In the Great Britain power system, reduced system inertia (particularly during low demand conditions) and larger possible infeed loss would make grid frequency regulation extremely challenging in future. Traditional primary frequency response could be insufficient to limit the frequency variation within acceptable range. This paper shows that thermostatically controlled loads (TCLs) (domestic refrigerators) can be controlled without real-time communication and in a nondisruptive way to collectively enhance the network frequency response. The aggregated power consumption of TCLs, distributed across the system, could be controlled as a `linear' function of the locally measured frequency and its rate of change. Alternatively, their aggregated consumption could be made to follow a `pre-set' power profile depending on the estimated infeed loss. A novel technique for accurate estimation of infeed loss and consequent postfault TCL power reduction is also proposed. The effectiveness of the two TCL control strategies is compared for primary and secondary frequency response through a case study on a 36 busbar reduced equivalent of the Great Britain power system. The effect of spatial variation of transient frequencies and the time delays in frequency measurement and filtering are considered to show how the TCLs can realistically provide rapid frequency response.

Advanced control of thermostatic loads for rapid frequency response in Great Britain / Trovato, Vincenzo; Martínez Sanz, Inmaculada; Chaudhuri, Balarko; Strbac, Goran. - In: IEEE TRANSACTIONS ON POWER SYSTEMS. - ISSN 0885-8950. - 2017, 32:3(2017), pp. 2106-2117. [10.1109/TPWRS.2016.2604044]

Advanced control of thermostatic loads for rapid frequency response in Great Britain

Trovato, Vincenzo;
2017-01-01

Abstract

In the Great Britain power system, reduced system inertia (particularly during low demand conditions) and larger possible infeed loss would make grid frequency regulation extremely challenging in future. Traditional primary frequency response could be insufficient to limit the frequency variation within acceptable range. This paper shows that thermostatically controlled loads (TCLs) (domestic refrigerators) can be controlled without real-time communication and in a nondisruptive way to collectively enhance the network frequency response. The aggregated power consumption of TCLs, distributed across the system, could be controlled as a `linear' function of the locally measured frequency and its rate of change. Alternatively, their aggregated consumption could be made to follow a `pre-set' power profile depending on the estimated infeed loss. A novel technique for accurate estimation of infeed loss and consequent postfault TCL power reduction is also proposed. The effectiveness of the two TCL control strategies is compared for primary and secondary frequency response through a case study on a 36 busbar reduced equivalent of the Great Britain power system. The effect of spatial variation of transient frequencies and the time delays in frequency measurement and filtering are considered to show how the TCLs can realistically provide rapid frequency response.
2017
3
Trovato, Vincenzo; Martínez Sanz, Inmaculada; Chaudhuri, Balarko; Strbac, Goran
Advanced control of thermostatic loads for rapid frequency response in Great Britain / Trovato, Vincenzo; Martínez Sanz, Inmaculada; Chaudhuri, Balarko; Strbac, Goran. - In: IEEE TRANSACTIONS ON POWER SYSTEMS. - ISSN 0885-8950. - 2017, 32:3(2017), pp. 2106-2117. [10.1109/TPWRS.2016.2604044]
File in questo prodotto:
File Dimensione Formato  
Publication_9.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.61 MB
Formato Adobe PDF
4.61 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/317274
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 92
  • ???jsp.display-item.citation.isi??? 80
social impact