Due to the large expected instantaneous luminosity, the future HL-LHC upgrade sets strong requirements on the radiation hardness of the CMS detector Inner Tracker. Sensors based on 3D pixel technology, with its superior radiation tolerance, comply with these extreme conditions. A full study and characterization of pixelated 3D sensors fabricated by FBK is presented here. The sensors were bump-bonded to RD53A readout chips and measured at several CERN SPS test beams. Results on charge collection and efficiency, for both non-irradiated and irradiated up to 1016 neq/cm2 samples, are presented. Two main studies are described: in the first the behaviour of the sensor is qualified as a function of irradiation, while kept under identical conditions; in the second the response is measured under typical operating conditions.
Test beam characterization of irradiated 3D pixel sensors / Garcia Alonso, A.; Curras, E.; Duarte-Campderros, J.; Fernandez, M.; Gomez, G.; Gonzalez, J.; Silva, E.; Vila, I.; Jaramillo, R.; Meschini, M.; Ceccarelli, R.; Dinardo, M.; Gennai, S.; Moroni, L.; Zuolo, D.; Demaria, N.; Monteil, E.; Gaioni, L.; Messineo, A.; Dalla Betta, G.; Mendicino, R.; Boscardin, M.; Hidalgo, S.; Merlos, A.; Pellegrini, G.; Quirion, D.; Manna, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 15:3(2020), pp. C03017.1-C03017.9. [10.1088/1748-0221/15/03/C03017]
Test beam characterization of irradiated 3D pixel sensors
Dalla Betta, G.;Mendicino, R.;Boscardin, M.;
2020-01-01
Abstract
Due to the large expected instantaneous luminosity, the future HL-LHC upgrade sets strong requirements on the radiation hardness of the CMS detector Inner Tracker. Sensors based on 3D pixel technology, with its superior radiation tolerance, comply with these extreme conditions. A full study and characterization of pixelated 3D sensors fabricated by FBK is presented here. The sensors were bump-bonded to RD53A readout chips and measured at several CERN SPS test beams. Results on charge collection and efficiency, for both non-irradiated and irradiated up to 1016 neq/cm2 samples, are presented. Two main studies are described: in the first the behaviour of the sensor is qualified as a function of irradiation, while kept under identical conditions; in the second the response is measured under typical operating conditions.File | Dimensione | Formato | |
---|---|---|---|
JINST_2020_3.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
3.71 MB
Formato
Adobe PDF
|
3.71 MB | Adobe PDF | Visualizza/Apri |