The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) calls for new highly radiation tolerant silicon pixel sensors, capable of withstanding fluences up to 2.3 × 1016 neq/cm2 (1 MeV equivalent neutrons). In this paper results obtained in beam test experiments with 3D and planar pixel sensors interconnected with the RD53A readout chip are reported. RD53A is the first prototype in 65 nm technology issued by the RD53 collaboration for the future readout chip to be used in the upgraded pixel detectors. The interconnected modules have been tested in an electron beam at DESY, before and after irradiation, which was performed at the CERN IRRAD facility for the 3D sensors or at the KIT Irradiation Center for the planar sensors, up to an equivalent fluence of 1 × 1016 neq/cm2. The sensors were made by FBK foundry in Trento, Italy, and their development was done in collaboration with INFN (Istituto Nazionale di Fisica Nucleare, Italy). The analysis of the collected data shows hit detection efficiencies around 99% measured after irradiation. All results are obtained in the framework of the CMS R&D activities.

Performances of highly irradiated 3d and planar pixel sensors interconnected to the RD53A readout chip / Cassese, A.; Ceccarelli, R.; Meschini, M.; Viliani, L.; Dinardo, M.; Gennai, S.; Moroni, L.; Zuolo, D.; Messineo, A.; Dalla Betta, G. F.; Boscardin, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 15:2(2020), pp. C02016.1-C02016.10. [10.1088/1748-0221/15/02/C02016]

Performances of highly irradiated 3d and planar pixel sensors interconnected to the RD53A readout chip

Dalla Betta G. F.;Boscardin M.
2020-01-01

Abstract

The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) calls for new highly radiation tolerant silicon pixel sensors, capable of withstanding fluences up to 2.3 × 1016 neq/cm2 (1 MeV equivalent neutrons). In this paper results obtained in beam test experiments with 3D and planar pixel sensors interconnected with the RD53A readout chip are reported. RD53A is the first prototype in 65 nm technology issued by the RD53 collaboration for the future readout chip to be used in the upgraded pixel detectors. The interconnected modules have been tested in an electron beam at DESY, before and after irradiation, which was performed at the CERN IRRAD facility for the 3D sensors or at the KIT Irradiation Center for the planar sensors, up to an equivalent fluence of 1 × 1016 neq/cm2. The sensors were made by FBK foundry in Trento, Italy, and their development was done in collaboration with INFN (Istituto Nazionale di Fisica Nucleare, Italy). The analysis of the collected data shows hit detection efficiencies around 99% measured after irradiation. All results are obtained in the framework of the CMS R&D activities.
2020
2
Cassese, A.; Ceccarelli, R.; Meschini, M.; Viliani, L.; Dinardo, M.; Gennai, S.; Moroni, L.; Zuolo, D.; Messineo, A.; Dalla Betta, G. F.; Boscardin, M...espandi
Performances of highly irradiated 3d and planar pixel sensors interconnected to the RD53A readout chip / Cassese, A.; Ceccarelli, R.; Meschini, M.; Viliani, L.; Dinardo, M.; Gennai, S.; Moroni, L.; Zuolo, D.; Messineo, A.; Dalla Betta, G. F.; Boscardin, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 15:2(2020), pp. C02016.1-C02016.10. [10.1088/1748-0221/15/02/C02016]
File in questo prodotto:
File Dimensione Formato  
JINST_2020_1.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.97 MB
Formato Adobe PDF
2.97 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/293895
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex ND
social impact