In this paper we present a position-sensitive detector based on the vertical integration of pairs of aligned pixels operating in Geiger-mode regime and designed for charged particle detection. This novel device exploits the coincidence between two simultaneous avalanche events to discriminate between particle-triggered detections and dark counts. This concept allows to have a reduced material budget and low power consumption in spite of a high granularity and fast timing response. A proof-of-principle prototype was designed and fabricated in a 150 nm CMOS process and vertically integrated through bump bonding. This first demonstrator has been characterized and tested with a high energy particle beams at CERN SPS/PS facilities, in different configurations, featuring a reduction of the dark-count rate (DCR) at room temperature from ∼100 kHz/mm2 to about 24 Hz/mm2 a particle detection efficiency limited only by the geometric factor. The device radiation tolerance has been investigated, vi...
In this paper we present a position-sensitive detector based on the vertical integration of pairs of aligned pixels operating in Geiger-mode regime and designed for charged particle detection. This novel device exploits the coincidence between two simultaneous avalanche events to discriminate between particle-triggered detections and dark counts. This concept allows to have a reduced material budget and low power consumption in spite of a high granularity and fast timing response. A proof-of-principle prototype was designed and fabricated in a 150 nm CMOS process and vertically integrated through bump bonding. This first demonstrator has been characterized and tested with a high energy particle beams at CERN SPS/PS facilities, in different configurations, featuring a reduction of the dark-count rate (DCR) at room temperature from ∼100 kHz/mm2 to about 24 Hz/mm2 a particle detection efficiency limited only by the geometric factor. The device radiation tolerance has been investigated, via irradiation of single tiers with 10 keV X-rays up to a dose of 1 Mrad (SiO2) and with neutrons up to a fluence of 1011 cm−2. A second prototype, addressing the goal to improve the present fill-factor, has been designed, manufactured and approaches now the characterization phase. Potential applications of this sensor include high spatial resolution tracking in high-energy experiments, radiation monitoring in space and radiation imaging in nuclear medicine. A small hand-held demonstrator is under construction for radio-guided surgery.
APiX, a two-tier avalanche pixel sensor for digital charged particle detection / Brogi, P., Bigongiari, G., Checchia, C., Collazuol, G., Dalla Betta, G.F., Ficorella, A., Marrocchesi, P.S., Morsani, F., Musacci, M., Torilla, G., Pancheri, L., Ratti, L., Savoy-Navarro, A., Silvestrin, L., Stolzi, F., Suh, J.E., Sulaj, A., Vacchi, C., Zarghami, M.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 958:(2020), pp. 162546.1-162546.5. [10.1016/j.nima.2019.162546]
APiX, a two-tier avalanche pixel sensor for digital charged particle detection
Dalla Betta G. F.;Pancheri L.;Zarghami M.
2020-01-01
Abstract
In this paper we present a position-sensitive detector based on the vertical integration of pairs of aligned pixels operating in Geiger-mode regime and designed for charged particle detection. This novel device exploits the coincidence between two simultaneous avalanche events to discriminate between particle-triggered detections and dark counts. This concept allows to have a reduced material budget and low power consumption in spite of a high granularity and fast timing response. A proof-of-principle prototype was designed and fabricated in a 150 nm CMOS process and vertically integrated through bump bonding. This first demonstrator has been characterized and tested with a high energy particle beams at CERN SPS/PS facilities, in different configurations, featuring a reduction of the dark-count rate (DCR) at room temperature from ∼100 kHz/mm2 to about 24 Hz/mm2 a particle detection efficiency limited only by the geometric factor. The device radiation tolerance has been investigated, vi...| File | Dimensione | Formato | |
|---|---|---|---|
|
NIMA_2020_3.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.07 MB
Formato
Adobe PDF
|
1.07 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione



