Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
An overview is provided of the 15 neutron beam instruments making up the initial instrument suite of the European Spallation Source (ESS), and being made available to the neutron user community. The ESS neutron source consists of a high-power accelerator and target station, providing a unique long-pulse time structure of slow neutrons. The design considerations behind the time structure, moderator geometry and instrument layout are presented. The 15-instrument suite consists of two small-angle instruments, two reflectometers, an imaging beamline, two single-crystal diffractometers; one for macromolecular crystallography and one for magnetism, two powder diffractometers, and an engineering diffractometer, as well as an array of five inelastic instruments comprising two chopper spectrometers, an inverse-geometry single-crystal excitations spectrometer, an instrument for vibrational spectroscopy and a high-resolution backscattering spectrometer. The conceptual design, performance and scientific drivers of each of these instruments are described. All of the instruments are designed to provide breakthrough new scientific capability, not currently available at existing facilities, building on the inherent strengths of the ESS long-pulse neutron source of high flux, flexible resolution and large bandwidth. Each of them is predicted to provide world-leading performance at an accelerator power of 2 MW. This technical capability translates into a very broad range of scientific capabilities. The composition of the instrument suite has been chosen to maximise the breadth and depth of the scientific impact of the early years of the ESS, and provide a solid base for completion and further expansion of the facility.
The instrument suite of the European Spallation Source / Andersen, K. H.; Argyriou, D. N.; Jackson, A. J.; Houston, J.; Henry, P. F.; Deen, P. P.; Toft-Petersen, R.; Beran, P.; Strobl, M.; Arnold, T.; Wacklin-Knecht, H.; Tsapatsaris, N.; Oksanen, E.; Woracek, R.; Schweika, W.; Mannix, D.; Hiess, A.; Kennedy, S.; Kirstein, O.; Petersson Arskold, S.; Taylor, J.; Hagen, M. E.; Laszlo, G.; Kanaki, K.; Piscitelli, F.; Khaplanov, A.; Stefanescu, I.; Kittelmann, T.; Pfeiffer, D.; Hall-Wilton, R.; Lopez, C. I.; Aprigliano, G.; Whitelegg, L.; Moreira, F. Y.; Olsson, M.; Bordallo, H. N.; Martin-Rodriguez, D.; Schneider, H.; Sharp, M.; Hartl, M.; Nagy, G.; Ansell, S.; Pullen, S.; Vickery, A.; Fedrigo, A.; Mezei, F.; Arai, M.; Heenan, R. K.; Halcrow, W.; Turner, D.; Raspino, D.; Orszulik, A.; Cooper, J.; Webb, N.; Galsworthy, P.; Nightingale, J.; Langridge, S.; Elmer, J.; Frielinghaus, H.; Hanslik, R.; Gussen, A.; Jaksch, S.; Engels, R.; Kozielewski, T.; Butterweck, S.; Feygenson, M.; Harbott, P.; Poque, A.; Schwaab, A.; Lieutenant, K.; Violini, N.; Voigt, J.; Bruckel, T.; Koenen, M.; Kammerling, H.; Babcock, E.; Salhi, Z.; Wischnewski, A.; Heynen, A.; Desert, S.; Jestin, J.; Porcher, F.; Fabreges, X.; Fabreges, G.; Annighofer, B.; Klimko, S.; Dupont, T.; Robillard, T.; Goukassov, A.; Longeville, S.; Alba-Simionesco, C.; Bourges, P.; Guyon Le Bouffy, J.; Lavie, P.; Rodrigues, S.; Calzada, E.; Lerche, M.; Schillinger, B.; Schmakat, P.; Schulz, M.; Seifert, M.; Lohstroh, W.; Petry, W.; Neuhaus, J.; Loaiza, L.; Tartaglione, A.; Glavic, A.; Schutz, S.; Stahn, J.; Lehmann, E.; Morgano, M.; Schefer, J.; Filges, U.; Klauser, C.; Niedermayer, C.; Fenske, J.; Nowak, G.; Rouijaa, M.; Siemers, D. J.; Kiehn, R.; Muller, M.; Carlsen, H.; Udby, L.; Lefmann, K.; Birk, J. O.; Holm-Dahlin, S.; Bertelsen, M.; Hansen, U. B.; Olsen, M. A.; Christensen, M.; Iversen, K.; Christensen, N. B.; Ronnow, H. M.; Freeman, P. G.; Hauback, B. C.; Kolevatov, R.; Llamas-Jansa, I.; Orecchini, A.; Sacchetti, F.; Petrillo, C.; Paciaroni, A.; Tozzi, P.; Zanatta, M.; Luna, P.; Herranz, I.; del Moral, O. G.; Huerta, M.; Magan, M.; Mosconi, M.; Abad, E.; Aguilar, J.; Stepanyan, S.; Bakedano, G.; Vivanco, R.; Bustinduy, I.; Sordo, F.; Martinez, J. L.; Lechner, R. E.; Villacorta, F. J.; Saroun, J.; Lukas, P.; Marko, M.; Zanetti, M.; Bellissima, S.; del Rosso, L.; Masi, F.; Bovo, C.; Chowdhury, M.; De Bonis, A.; Di Fresco, L.; Scatigno, C.; Parker, S. F.; Fernandez-Alonso, F.; Colognesi, D.; Senesi, R.; Andreani, C.; Gorini, G.; Scionti, G.; Schreyer, A.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 957:(2020), p. 163402. [10.1016/j.nima.2020.163402]
The instrument suite of the European Spallation Source
Andersen K. H.;Argyriou D. N.;Jackson A. J.;Houston J.;Henry P. F.;Deen P. P.;Toft-Petersen R.;Beran P.;Strobl M.;Arnold T.;Wacklin-Knecht H.;Tsapatsaris N.;Oksanen E.;Woracek R.;Schweika W.;Mannix D.;Hiess A.;Kennedy S.;Kirstein O.;Petersson Arskold S.;Taylor J.;Hagen M. E.;Laszlo G.;Kanaki K.;Piscitelli F.;Khaplanov A.;Stefanescu I.;Kittelmann T.;Pfeiffer D.;Hall-Wilton R.;Lopez C. I.;Aprigliano G.;Whitelegg L.;Moreira F. Y.;Olsson M.;Bordallo H. N.;Martin-Rodriguez D.;Schneider H.;Sharp M.;Hartl M.;Nagy G.;Ansell S.;Pullen S.;Vickery A.;Fedrigo A.;Mezei F.;Arai M.;Heenan R. K.;Halcrow W.;Turner D.;Raspino D.;Orszulik A.;Cooper J.;Webb N.;Galsworthy P.;Nightingale J.;Langridge S.;Elmer J.;Frielinghaus H.;Hanslik R.;Gussen A.;Jaksch S.;Engels R.;Kozielewski T.;Butterweck S.;Feygenson M.;Harbott P.;Poque A.;Schwaab A.;Lieutenant K.;Violini N.;Voigt J.;Bruckel T.;Koenen M.;Kammerling H.;Babcock E.;Salhi Z.;Wischnewski A.;Heynen A.;Desert S.;Jestin J.;Porcher F.;Fabreges X.;Fabreges G.;Annighofer B.;Klimko S.;Dupont T.;Robillard T.;Goukassov A.;Longeville S.;Alba-Simionesco C.;Bourges P.;Guyon Le Bouffy J.;Lavie P.;Rodrigues S.;Calzada E.;Lerche M.;Schillinger B.;Schmakat P.;Schulz M.;Seifert M.;Lohstroh W.;Petry W.;Neuhaus J.;Loaiza L.;Tartaglione A.;Glavic A.;Schutz S.;Stahn J.;Lehmann E.;Morgano M.;Schefer J.;Filges U.;Klauser C.;Niedermayer C.;Fenske J.;Nowak G.;Rouijaa M.;Siemers D. J.;Kiehn R.;Muller M.;Carlsen H.;Udby L.;Lefmann K.;Birk J. O.;Holm-Dahlin S.;Bertelsen M.;Hansen U. B.;Olsen M. A.;Christensen M.;Iversen K.;Christensen N. B.;Ronnow H. M.;Freeman P. G.;Hauback B. C.;Kolevatov R.;Llamas-Jansa I.;Orecchini A.;Sacchetti F.;Petrillo C.;Paciaroni A.;Tozzi P.;Zanatta M.;Luna P.;Herranz I.;del Moral O. G.;Huerta M.;Magan M.;Mosconi M.;Abad E.;Aguilar J.;Stepanyan S.;Bakedano G.;Vivanco R.;Bustinduy I.;Sordo F.;Martinez J. L.;Lechner R. E.;Villacorta F. J.;Saroun J.;Lukas P.;Marko M.;Zanetti M.;Bellissima S.;del Rosso L.;Masi F.;Bovo C.;Chowdhury M.;De Bonis A.;Di Fresco L.;Scatigno C.;Parker S. F.;Fernandez-Alonso F.;Colognesi D.;Senesi R.;Andreani C.;Gorini G.;Scionti G.;Schreyer A.
2020-01-01
Abstract
An overview is provided of the 15 neutron beam instruments making up the initial instrument suite of the European Spallation Source (ESS), and being made available to the neutron user community. The ESS neutron source consists of a high-power accelerator and target station, providing a unique long-pulse time structure of slow neutrons. The design considerations behind the time structure, moderator geometry and instrument layout are presented. The 15-instrument suite consists of two small-angle instruments, two reflectometers, an imaging beamline, two single-crystal diffractometers; one for macromolecular crystallography and one for magnetism, two powder diffractometers, and an engineering diffractometer, as well as an array of five inelastic instruments comprising two chopper spectrometers, an inverse-geometry single-crystal excitations spectrometer, an instrument for vibrational spectroscopy and a high-resolution backscattering spectrometer. The conceptual design, performance and scientific drivers of each of these instruments are described. All of the instruments are designed to provide breakthrough new scientific capability, not currently available at existing facilities, building on the inherent strengths of the ESS long-pulse neutron source of high flux, flexible resolution and large bandwidth. Each of them is predicted to provide world-leading performance at an accelerator power of 2 MW. This technical capability translates into a very broad range of scientific capabilities. The composition of the instrument suite has been chosen to maximise the breadth and depth of the scientific impact of the early years of the ESS, and provide a solid base for completion and further expansion of the facility.
Andersen, K. H.; Argyriou, D. N.; Jackson, A. J.; Houston, J.; Henry, P. F.; Deen, P. P.; Toft-Petersen, R.; Beran, P.; Strobl, M.; Arnold, T.; Wackli...espandi
The instrument suite of the European Spallation Source / Andersen, K. H.; Argyriou, D. N.; Jackson, A. J.; Houston, J.; Henry, P. F.; Deen, P. P.; Toft-Petersen, R.; Beran, P.; Strobl, M.; Arnold, T.; Wacklin-Knecht, H.; Tsapatsaris, N.; Oksanen, E.; Woracek, R.; Schweika, W.; Mannix, D.; Hiess, A.; Kennedy, S.; Kirstein, O.; Petersson Arskold, S.; Taylor, J.; Hagen, M. E.; Laszlo, G.; Kanaki, K.; Piscitelli, F.; Khaplanov, A.; Stefanescu, I.; Kittelmann, T.; Pfeiffer, D.; Hall-Wilton, R.; Lopez, C. I.; Aprigliano, G.; Whitelegg, L.; Moreira, F. Y.; Olsson, M.; Bordallo, H. N.; Martin-Rodriguez, D.; Schneider, H.; Sharp, M.; Hartl, M.; Nagy, G.; Ansell, S.; Pullen, S.; Vickery, A.; Fedrigo, A.; Mezei, F.; Arai, M.; Heenan, R. K.; Halcrow, W.; Turner, D.; Raspino, D.; Orszulik, A.; Cooper, J.; Webb, N.; Galsworthy, P.; Nightingale, J.; Langridge, S.; Elmer, J.; Frielinghaus, H.; Hanslik, R.; Gussen, A.; Jaksch, S.; Engels, R.; Kozielewski, T.; Butterweck, S.; Feygenson, M.; Harbott, P.; Poque, A.; Schwaab, A.; Lieutenant, K.; Violini, N.; Voigt, J.; Bruckel, T.; Koenen, M.; Kammerling, H.; Babcock, E.; Salhi, Z.; Wischnewski, A.; Heynen, A.; Desert, S.; Jestin, J.; Porcher, F.; Fabreges, X.; Fabreges, G.; Annighofer, B.; Klimko, S.; Dupont, T.; Robillard, T.; Goukassov, A.; Longeville, S.; Alba-Simionesco, C.; Bourges, P.; Guyon Le Bouffy, J.; Lavie, P.; Rodrigues, S.; Calzada, E.; Lerche, M.; Schillinger, B.; Schmakat, P.; Schulz, M.; Seifert, M.; Lohstroh, W.; Petry, W.; Neuhaus, J.; Loaiza, L.; Tartaglione, A.; Glavic, A.; Schutz, S.; Stahn, J.; Lehmann, E.; Morgano, M.; Schefer, J.; Filges, U.; Klauser, C.; Niedermayer, C.; Fenske, J.; Nowak, G.; Rouijaa, M.; Siemers, D. J.; Kiehn, R.; Muller, M.; Carlsen, H.; Udby, L.; Lefmann, K.; Birk, J. O.; Holm-Dahlin, S.; Bertelsen, M.; Hansen, U. B.; Olsen, M. A.; Christensen, M.; Iversen, K.; Christensen, N. B.; Ronnow, H. M.; Freeman, P. G.; Hauback, B. C.; Kolevatov, R.; Llamas-Jansa, I.; Orecchini, A.; Sacchetti, F.; Petrillo, C.; Paciaroni, A.; Tozzi, P.; Zanatta, M.; Luna, P.; Herranz, I.; del Moral, O. G.; Huerta, M.; Magan, M.; Mosconi, M.; Abad, E.; Aguilar, J.; Stepanyan, S.; Bakedano, G.; Vivanco, R.; Bustinduy, I.; Sordo, F.; Martinez, J. L.; Lechner, R. E.; Villacorta, F. J.; Saroun, J.; Lukas, P.; Marko, M.; Zanetti, M.; Bellissima, S.; del Rosso, L.; Masi, F.; Bovo, C.; Chowdhury, M.; De Bonis, A.; Di Fresco, L.; Scatigno, C.; Parker, S. F.; Fernandez-Alonso, F.; Colognesi, D.; Senesi, R.; Andreani, C.; Gorini, G.; Scionti, G.; Schreyer, A.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 957:(2020), p. 163402. [10.1016/j.nima.2020.163402]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/269746
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
105
88
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.