Model-based prediction of fractional flow reserve (FFR) in the context of stable coronary artery disease (CAD) diagnosis requires a number of modelling assumptions. One of these assumptions is the definition of a baseline coronary flow, ie, total coronary flow at rest prior to the administration of drugs needed to perform invasive measurements. Here we explore the impact of several methods available in the literature to estimate and distribute baseline coronary flow on FFR predictions obtained with a reduced-order model. We consider 63 patients with suspected stable CAD, for a total of 105 invasive FFR measurements. First, we improve a reduced-order model with respect to previous results and validate its performance versus results obtained with a 3D model. Next, we assess the impact of a wide range of methods to impose and distribute baseline coronary flow on FFR prediction, which proved to have a significant impact on diagnostic performance. However, none of the proposed methods resulted in a significant improvement of prediction error standard deviation. Finally, we show that intrinsic uncertainties related to stenosis geometry and the effect of hyperemic inducing drugs have to be addressed in order to improve FFR prediction accuracy.

Impact of baseline coronary flow and its distribution on fractional flow reserve prediction / Muller, L. O.; Fossan, F. E.; Braten, A. T.; Jorgensen, A.; Wiseth, R.; Hellevik, L. R.. - In: INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING. - ISSN 2040-7939. - 2019:(2019), pp. 324601-324625. [10.1002/cnm.3246]

Impact of baseline coronary flow and its distribution on fractional flow reserve prediction

Muller L. O.;
2019-01-01

Abstract

Model-based prediction of fractional flow reserve (FFR) in the context of stable coronary artery disease (CAD) diagnosis requires a number of modelling assumptions. One of these assumptions is the definition of a baseline coronary flow, ie, total coronary flow at rest prior to the administration of drugs needed to perform invasive measurements. Here we explore the impact of several methods available in the literature to estimate and distribute baseline coronary flow on FFR predictions obtained with a reduced-order model. We consider 63 patients with suspected stable CAD, for a total of 105 invasive FFR measurements. First, we improve a reduced-order model with respect to previous results and validate its performance versus results obtained with a 3D model. Next, we assess the impact of a wide range of methods to impose and distribute baseline coronary flow on FFR prediction, which proved to have a significant impact on diagnostic performance. However, none of the proposed methods resulted in a significant improvement of prediction error standard deviation. Finally, we show that intrinsic uncertainties related to stenosis geometry and the effect of hyperemic inducing drugs have to be addressed in order to improve FFR prediction accuracy.
2019
Muller, L. O.; Fossan, F. E.; Braten, A. T.; Jorgensen, A.; Wiseth, R.; Hellevik, L. R.
Impact of baseline coronary flow and its distribution on fractional flow reserve prediction / Muller, L. O.; Fossan, F. E.; Braten, A. T.; Jorgensen, A.; Wiseth, R.; Hellevik, L. R.. - In: INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING. - ISSN 2040-7939. - 2019:(2019), pp. 324601-324625. [10.1002/cnm.3246]
File in questo prodotto:
File Dimensione Formato  
cnm.3246.pdf

accesso aperto

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Creative commons
Dimensione 1.36 MB
Formato Adobe PDF
1.36 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/257197
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 38
  • OpenAlex ND
social impact