Background: Due to the growing epidemic of atrial fibrillation (AF), new strategies for AF screening, diagnosis, and monitoring are required. Wearable devices with on-board AF detection algorithms may improve early diagnosis and therapy outcomes. In this work, we implemented optimized algorithms for AF detection on a wearable ECG monitoring device and assessed their performance. Methods: The signal processing framework was composed of two main modules: 1) a QRS detector based on a finite state machine, and 2) an AF detector based on the Shannon entropy of the symbolic word series obtained from the instantaneous heart rate. The AF detector was optimized off-line by tuning its parameters to reduce the computational burden while preserving detection accuracy. On-board performance was assessed in terms of detection accuracy, memory usage, and computation time. Results: The on-board implementation of the QRS detector produced an overall accuracy of 99% on the MIT-BIH Arrhythmia Database, with memory usage = 672 bytes, and computation time ≤90 μs. The on-board implementation of the optimized AF algorithm gave an overall accuracy of 98.1% (versus 98.3% of the original version) on the MIT-BIH AF Database, with increased sensitivity (99.2% versus 98.5%) and decreased specificity (97.3% versus 98.2%), memory usage = 4648 bytes, and computation time ≤ 75 μs (consistent with real-time detection). Conclusions: This study demonstrated the feasibility of real-time AF detection on a wearable ECG device. It constitutes a promising step towards the development of novel ECG monitoring systems to tackle the growing AF epidemic.
Implementation and validation of real-time algorithms for atrial fibrillation detection on a wearable ECG device / Marsili, I. A.; Biasiolli, L.; Masè, M.; Adami, A.; Andrighetti, A. O.; Ravelli, F.; Nollo, G.. - In: COMPUTERS IN BIOLOGY AND MEDICINE. - ISSN 0010-4825. - 116:(2020), pp. 10354001-10354010. [10.1016/j.compbiomed.2019.103540]
Implementation and validation of real-time algorithms for atrial fibrillation detection on a wearable ECG device
Marsili, I. A.;Biasiolli, L.;Masè, M.;Adami, A.;Andrighetti, A. O.;Ravelli, F.;Nollo, G.
2020-01-01
Abstract
Background: Due to the growing epidemic of atrial fibrillation (AF), new strategies for AF screening, diagnosis, and monitoring are required. Wearable devices with on-board AF detection algorithms may improve early diagnosis and therapy outcomes. In this work, we implemented optimized algorithms for AF detection on a wearable ECG monitoring device and assessed their performance. Methods: The signal processing framework was composed of two main modules: 1) a QRS detector based on a finite state machine, and 2) an AF detector based on the Shannon entropy of the symbolic word series obtained from the instantaneous heart rate. The AF detector was optimized off-line by tuning its parameters to reduce the computational burden while preserving detection accuracy. On-board performance was assessed in terms of detection accuracy, memory usage, and computation time. Results: The on-board implementation of the QRS detector produced an overall accuracy of 99% on the MIT-BIH Arrhythmia Database, with memory usage = 672 bytes, and computation time ≤90 μs. The on-board implementation of the optimized AF algorithm gave an overall accuracy of 98.1% (versus 98.3% of the original version) on the MIT-BIH AF Database, with increased sensitivity (99.2% versus 98.5%) and decreased specificity (97.3% versus 98.2%), memory usage = 4648 bytes, and computation time ≤ 75 μs (consistent with real-time detection). Conclusions: This study demonstrated the feasibility of real-time AF detection on a wearable ECG device. It constitutes a promising step towards the development of novel ECG monitoring systems to tackle the growing AF epidemic.File | Dimensione | Formato | |
---|---|---|---|
Computers in Biology and Medicine 2020.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.63 MB
Formato
Adobe PDF
|
1.63 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione