The experimental out-of-plane performance of timber-to-timber composite floor structures was experimentally investigated. Specifically, 6-point bending tests were performed on seventeen full-scale floor specimens (6.4m span) assembled with inclined screw fasteners (both single threaded and double threaded screws) and by using combinations of different timber products (e.g. spruce cross laminated panels, beech laminated veneer lumber beams/panels). For most of the specimens, a cambering and pre-stressing technique (CP procedure) was utilised by exploiting the compression force produced by screw fasteners. The experimental observations indicated that it is possible to obtain camber values that go from approximately 1/900 to 1/250 of the floor span, according to the design needs. As an indicator of the wide possible range of pre-stress forces, the vertical force required to eliminate the camber was monitored during testing, resulting in measured values ranging from 2.4 kN/m2 to 13.8 kN/m2 (0.6m joist spacing). The applicability of the proposed solutions in real design scenarios was evaluated by comparing the experimental results with the predictions obtained by using a proposed analytical approach. A good correlation was observed between the test data and the theoretical predictions.

Experimental testing of pre-stressed timber-to-timber composite (TTC) floors / Giongo, Ivan; Schiro, Gianni; Walsh, Kevin; Riccadonna, Daniele. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - ELETTRONICO. - 2019 vol. 201:(2019).

Experimental testing of pre-stressed timber-to-timber composite (TTC) floors

Ivan Giongo;Gianni Schiro;Daniele Riccadonna
2019-01-01

Abstract

The experimental out-of-plane performance of timber-to-timber composite floor structures was experimentally investigated. Specifically, 6-point bending tests were performed on seventeen full-scale floor specimens (6.4m span) assembled with inclined screw fasteners (both single threaded and double threaded screws) and by using combinations of different timber products (e.g. spruce cross laminated panels, beech laminated veneer lumber beams/panels). For most of the specimens, a cambering and pre-stressing technique (CP procedure) was utilised by exploiting the compression force produced by screw fasteners. The experimental observations indicated that it is possible to obtain camber values that go from approximately 1/900 to 1/250 of the floor span, according to the design needs. As an indicator of the wide possible range of pre-stress forces, the vertical force required to eliminate the camber was monitored during testing, resulting in measured values ranging from 2.4 kN/m2 to 13.8 kN/m2 (0.6m joist spacing). The applicability of the proposed solutions in real design scenarios was evaluated by comparing the experimental results with the predictions obtained by using a proposed analytical approach. A good correlation was observed between the test data and the theoretical predictions.
2019
Giongo, Ivan; Schiro, Gianni; Walsh, Kevin; Riccadonna, Daniele
Experimental testing of pre-stressed timber-to-timber composite (TTC) floors / Giongo, Ivan; Schiro, Gianni; Walsh, Kevin; Riccadonna, Daniele. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - ELETTRONICO. - 2019 vol. 201:(2019).
File in questo prodotto:
File Dimensione Formato  
Postprint_Experimental testing of prestressed TTC floors.pdf

Solo gestori archivio

Tipologia: Post-print referato (Refereed author’s manuscript)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.87 MB
Formato Adobe PDF
1.87 MB Adobe PDF   Visualizza/Apri
1-s2.0-S0141029619322230-main.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 15.42 MB
Formato Adobe PDF
15.42 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/244210
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact