This article studies the use of sound spectral analysis as a possible diagnostic technique for the assessment of existing timber structures. The idea is to analyze the spectrum of the sound that is generated by hitting a wood surface with a hammer (or an equivalent tool) and is recorded by a microphone. The sound spectrum and its relevant indicators are compared to reference data obtained for sound wood, in order to detect the presence of damage/decay. A first insight on the method applicability was obtained by testing the technique on 10 timber specimens in different conditions, from sound to completely decayed. The study was then expanded on 20 more beams (10 with a 2 m span and 10 with a 4 m span) that were tested in sound conditions and after an induced damage. Recording of the signals was obtained by using different mid-market smartphone microphones and a professional microphone. Moment analysis was used to evaluate and compare the experimental data. The parameters that were expected to have the most significant impact on the sound signal (e.g., impact location, boundary conditions, etc.) and that can negatively influence the assessment were then identified and investigated.
Acoustic Testing for the Preliminary Assessment of Timber Beams — A Pilot Study / Riccadonna, Daniele; Giongo, I.; Casagrande, D.; Piazza, M.. - In: INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE. - ISSN 1558-3058. - 2019:(2019), pp. 1-13. [10.1080/15583058.2019.1598516]
Acoustic Testing for the Preliminary Assessment of Timber Beams — A Pilot Study
Riccadonna, Daniele;Giongo I.;Casagrande D.;Piazza M.
2019-01-01
Abstract
This article studies the use of sound spectral analysis as a possible diagnostic technique for the assessment of existing timber structures. The idea is to analyze the spectrum of the sound that is generated by hitting a wood surface with a hammer (or an equivalent tool) and is recorded by a microphone. The sound spectrum and its relevant indicators are compared to reference data obtained for sound wood, in order to detect the presence of damage/decay. A first insight on the method applicability was obtained by testing the technique on 10 timber specimens in different conditions, from sound to completely decayed. The study was then expanded on 20 more beams (10 with a 2 m span and 10 with a 4 m span) that were tested in sound conditions and after an induced damage. Recording of the signals was obtained by using different mid-market smartphone microphones and a professional microphone. Moment analysis was used to evaluate and compare the experimental data. The parameters that were expected to have the most significant impact on the sound signal (e.g., impact location, boundary conditions, etc.) and that can negatively influence the assessment were then identified and investigated.File | Dimensione | Formato | |
---|---|---|---|
Post-print_Acoustic testing for the preliminary assessment of timber beams.pdf
Solo gestori archivio
Tipologia:
Post-print referato (Refereed author’s manuscript)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.97 MB
Formato
Adobe PDF
|
1.97 MB | Adobe PDF | Visualizza/Apri |
Acoustic Testing for the Preliminary Assessment of Timber Beams A Pilot Study.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.72 MB
Formato
Adobe PDF
|
2.72 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione