The dependence of electrical breakdown on the rate of change of voltage between the electrodes is investigated for VHB4905, a very common polyacrylate adhesive tape produced by 3M with interesting dielectric properties. If voltage is applied according to a quasi.static loading protocol, it is found that the dielectric strength of the tape VHB4905 can increase from 35 to 70 kV/mm, depending on the uniaxial prestretch applied in the considered range: 0.500%. In the case of a voltage pulse, the dielectric strength depends on voltage intensity at the leading edge of the pulse. In particular, for the considered duration of the leading edge of the voltage pulse (~20 ns), a breakdown strength threshold (minimum breakdown voltage) has been found, being 3.7 times larger than the breakdown strength measured under quasi.static loading conditions.
Experimental Analysis on Electrical Breakdown of Acrylic VHB Tape under Quasi-Static and Pulsed Voltage / Smirnov, I. V.; Springhetti, R.; Morozov, V. A.; Lukin, A. A.. - In: TECHNICAL PHYSICS. - ISSN 1063-7842. - 63:1(2018), pp. 152-154. [10.1134/S1063784218010231]
Experimental Analysis on Electrical Breakdown of Acrylic VHB Tape under Quasi-Static and Pulsed Voltage
R. Springhetti;
2018-01-01
Abstract
The dependence of electrical breakdown on the rate of change of voltage between the electrodes is investigated for VHB4905, a very common polyacrylate adhesive tape produced by 3M with interesting dielectric properties. If voltage is applied according to a quasi.static loading protocol, it is found that the dielectric strength of the tape VHB4905 can increase from 35 to 70 kV/mm, depending on the uniaxial prestretch applied in the considered range: 0.500%. In the case of a voltage pulse, the dielectric strength depends on voltage intensity at the leading edge of the pulse. In particular, for the considered duration of the leading edge of the voltage pulse (~20 ns), a breakdown strength threshold (minimum breakdown voltage) has been found, being 3.7 times larger than the breakdown strength measured under quasi.static loading conditions.File | Dimensione | Formato | |
---|---|---|---|
Smirnov2018_Article_ExperimentalAnalysisOnElectric.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
314.41 kB
Formato
Adobe PDF
|
314.41 kB | Adobe PDF | Visualizza/Apri |
2018_ExperimentalSMIRNOV_RU.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
94.86 kB
Formato
Adobe PDF
|
94.86 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione