Recognising that in situ conditions for URM walls rarely reflect the idealised conditions assumed in analytical predictive models, nineteen unreinforced masonry (URM) walls in six different buildings were physically tested in situ to establish their out-of-plane (OOP) force-displacement behaviour, and the measured results were compared to the forecasted results obtained from established predictive methods. The considered wall configurations represented a variety of geometries, boundary conditions, pre-test damage states, and material properties. The average ratio and associated coefficient of variation (CV) of predicted strengths to measured strengths were determined to be 0.84 (CV 0.56) and 0.93 (CV 0.25) for the “unbounded” and “bounded” wall conditions, respectively, where the latter group represents walls used to infill frames. Use of the existing predictive methods resulted in over-prediction of the measured displacement parameters, which was likely due to most of the predictive methods being based on historical walls tests in one-way spanning conditions and without rigid bounding restraints capable of effectuating arching action in the wall, in contrast to many of the wall test conditions employed in the current study.

Predicted Versus Experimental Out-of-plane Force-displacement Behaviour of Unreinforced Masonry Walls / Walsh, Kevin; Dizhur, Dmytro; Giongo, Ivan; Derakhshan, Hossein; Ingham, Jason. - In: STRUCTURES. - ISSN 2352-0124. - 2018:(2018). [10.1016/j.istruc.2018.07.012]

Predicted Versus Experimental Out-of-plane Force-displacement Behaviour of Unreinforced Masonry Walls

Ivan Giongo;
2018-01-01

Abstract

Recognising that in situ conditions for URM walls rarely reflect the idealised conditions assumed in analytical predictive models, nineteen unreinforced masonry (URM) walls in six different buildings were physically tested in situ to establish their out-of-plane (OOP) force-displacement behaviour, and the measured results were compared to the forecasted results obtained from established predictive methods. The considered wall configurations represented a variety of geometries, boundary conditions, pre-test damage states, and material properties. The average ratio and associated coefficient of variation (CV) of predicted strengths to measured strengths were determined to be 0.84 (CV 0.56) and 0.93 (CV 0.25) for the “unbounded” and “bounded” wall conditions, respectively, where the latter group represents walls used to infill frames. Use of the existing predictive methods resulted in over-prediction of the measured displacement parameters, which was likely due to most of the predictive methods being based on historical walls tests in one-way spanning conditions and without rigid bounding restraints capable of effectuating arching action in the wall, in contrast to many of the wall test conditions employed in the current study.
2018
Walsh, Kevin; Dizhur, Dmytro; Giongo, Ivan; Derakhshan, Hossein; Ingham, Jason
Predicted Versus Experimental Out-of-plane Force-displacement Behaviour of Unreinforced Masonry Walls / Walsh, Kevin; Dizhur, Dmytro; Giongo, Ivan; Derakhshan, Hossein; Ingham, Jason. - In: STRUCTURES. - ISSN 2352-0124. - 2018:(2018). [10.1016/j.istruc.2018.07.012]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/211042
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 22
social impact