The analysis of amino acids presents significant challenges to contemporary analytical separations. The present paper investigates the possibility of retention prediction in hydrophilic interaction chromatography (HILIC) gradient elution based on the analytical solution of the fundamental equation of the multilinear gradient elution derived for reversed-phase systems. A simple linear dependence of the logarithm of the solute retention (ln k) upon the volume fraction of organic modifier (j) in a binary aqueousorganic mobile is adopted. Utility of the developed methodology was tested on the separation of a mixture of 21 amino acids carried out with 14 different gradient elution programs (from simple linear to multilinear and curved shaped) using ternary eluents in which a mixture of methanol and water (1:1, v/v) was the strong eluting member and acetonitrile was the weak solvent. Starting from at least two gradient runs, the prediction of solute retention obtained under all the rest gradients was excellent, even when curved gradient profiles were used. Development of such methodologies can be of great interest for a wide range of applications.

Retention prediction of a set of amino acids under gradient elution conditions in hydrophilic interaction liquid chromatography / Gika, Helen; Theodoridis, Georgios; Mattivi, Fulvio; Vrhovsek, Urska; Pappa Louisi, Adriani. - In: JOURNAL OF SEPARATION SCIENCE. - ISSN 1615-9306. - 35:3(2012), pp. 376-383. [10.1002/jssc.201100795]

Retention prediction of a set of amino acids under gradient elution conditions in hydrophilic interaction liquid chromatography

Mattivi, Fulvio;Vrhovsek, Urska;
2012-01-01

Abstract

The analysis of amino acids presents significant challenges to contemporary analytical separations. The present paper investigates the possibility of retention prediction in hydrophilic interaction chromatography (HILIC) gradient elution based on the analytical solution of the fundamental equation of the multilinear gradient elution derived for reversed-phase systems. A simple linear dependence of the logarithm of the solute retention (ln k) upon the volume fraction of organic modifier (j) in a binary aqueousorganic mobile is adopted. Utility of the developed methodology was tested on the separation of a mixture of 21 amino acids carried out with 14 different gradient elution programs (from simple linear to multilinear and curved shaped) using ternary eluents in which a mixture of methanol and water (1:1, v/v) was the strong eluting member and acetonitrile was the weak solvent. Starting from at least two gradient runs, the prediction of solute retention obtained under all the rest gradients was excellent, even when curved gradient profiles were used. Development of such methodologies can be of great interest for a wide range of applications.
2012
3
Gika, Helen; Theodoridis, Georgios; Mattivi, Fulvio; Vrhovsek, Urska; Pappa Louisi, Adriani
Retention prediction of a set of amino acids under gradient elution conditions in hydrophilic interaction liquid chromatography / Gika, Helen; Theodoridis, Georgios; Mattivi, Fulvio; Vrhovsek, Urska; Pappa Louisi, Adriani. - In: JOURNAL OF SEPARATION SCIENCE. - ISSN 1615-9306. - 35:3(2012), pp. 376-383. [10.1002/jssc.201100795]
File in questo prodotto:
File Dimensione Formato  
Gika_et_al_J_SEP_SCI_2012.pdf

Solo gestori archivio

Descrizione: articolo principale
Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 203.07 kB
Formato Adobe PDF
203.07 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/176200
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
  • OpenAlex ND
social impact