HeartLander is a small mobile robot which adheres to and navigates over the surface of the heart to provide therapies in a minimally invasive manner. HeartLander's ability to efficiently operate in this dynamic environment is greatly affected by physiological motion, namely the cardiac and respiration cycles. Synchronization of robot motion with minimal intrapericardial pressure results in safer and more efficient travel. The work presented models the physiological components of motion using Fourier series and estimates their parameters using an Extended Kalman Filter. Using the Fourier series parameters, estimates of physiological phase values are calculated to be used for step synchronization. The proposed methods are demonstrated on data from a HeartLander animal study for four locations on the heart. Mean respiration phase estimates are shown to be within 5% of the true respiration phases, while mean cardiac phase estimates are shown to have a minimum error of 11%.

Fourier modeling of porcine heartbeat and respiration in vivo for synchronization of HeartLander robot locomotion / Wood, N. A.; Patronik, N. A.; Zenati, M. A.; Riviere, C. N.. - (2011), pp. 7041-7044. ( IEEE EMBS 2011 Baltimore MD USA 10 Agosto 2011) [10.1109/IEMBS.2011.6091780].

Fourier modeling of porcine heartbeat and respiration in vivo for synchronization of HeartLander robot locomotion

Zenati M. A.;
2011-01-01

Abstract

HeartLander is a small mobile robot which adheres to and navigates over the surface of the heart to provide therapies in a minimally invasive manner. HeartLander's ability to efficiently operate in this dynamic environment is greatly affected by physiological motion, namely the cardiac and respiration cycles. Synchronization of robot motion with minimal intrapericardial pressure results in safer and more efficient travel. The work presented models the physiological components of motion using Fourier series and estimates their parameters using an Extended Kalman Filter. Using the Fourier series parameters, estimates of physiological phase values are calculated to be used for step synchronization. The proposed methods are demonstrated on data from a HeartLander animal study for four locations on the heart. Mean respiration phase estimates are shown to be within 5% of the true respiration phases, while mean cardiac phase estimates are shown to have a minimum error of 11%.
2011
Conf Proc IEEE Eng Med Biol Soc
New York USA
IEEE
9781424441211
Settore MEDS-13/C - Chirurgia cardiaca
Settore INFO-01/A - Informatica
Wood, N. A.; Patronik, N. A.; Zenati, M. A.; Riviere, C. N.
Fourier modeling of porcine heartbeat and respiration in vivo for synchronization of HeartLander robot locomotion / Wood, N. A.; Patronik, N. A.; Zenati, M. A.; Riviere, C. N.. - (2011), pp. 7041-7044. ( IEEE EMBS 2011 Baltimore MD USA 10 Agosto 2011) [10.1109/IEMBS.2011.6091780].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/474956
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex 1
social impact