As the climate changes, it is crucial to understand how indoor contaminants, rising temperatures, and fluctuating relative humidity (RH) — all influenced by global warming — affect perceived air quality (PAQ). Additionally, analyzing the impact of building-related factors (e.g., orientation, floor level) on PAQ is particularly important in office buildings where occupants often lack control over ventilation and shading systems. This research investigates the relationship between environmental factors, building-related factors, and PAQ in office settings. A field study was conducted in an office building in Bolzano (northern Italy). Carbon dioxide (CO2), particulate matter (PM1, PM2.5, PM10), total volatile organic compounds (TVOC), air temperature, and RH were continuously monitored for a 5-week period during winter 2023. PAQ was assessed through a "right-here right-now" questionnaire using a 7-point Likert scale (from ―very dissatisfied‖ to ―very satisfied‖). Fifty-five individuals participated voluntarily, and their subjective feedback was correlated with thermal and indoor air quality (IAQ) parameters and building-related factors using a multiple linear regression analysis. Results showed that low RH values are associated with greater dissatisfaction with PAQ, while lower temperature values are linked to higher satisfaction with PAQ. Among the air contaminants, PM10 and PM2.5 have statistically significant effects, with higher levels associated with lower satisfaction ratings. Orientation and office facing also influence PAQ satisfaction, with an outdoor view being more favorable than an indoor courtyard view, and a west orientation being the least favorable. The study demonstrates complex relationships between these predictors, their interactions, and PAQ satisfaction.

Influence of Indoor Air Pollutants, Temperature, Relative Humidity and Building-Related Factors on Perceived Air Quality (PAQ) in Office Buildings: Evidence from a Field Study / Torriani, G; Torresin, S; Lara-Ibeas, I; Albatici, R; Babich, F. - (2024), pp. 96-96. (Intervento presentato al convegno CATE 2024 tenutosi a Seville, Spain nel 20-22 November 2024).

Influence of Indoor Air Pollutants, Temperature, Relative Humidity and Building-Related Factors on Perceived Air Quality (PAQ) in Office Buildings: Evidence from a Field Study

Torriani, G;Torresin, S;Albatici, R;
2024-01-01

Abstract

As the climate changes, it is crucial to understand how indoor contaminants, rising temperatures, and fluctuating relative humidity (RH) — all influenced by global warming — affect perceived air quality (PAQ). Additionally, analyzing the impact of building-related factors (e.g., orientation, floor level) on PAQ is particularly important in office buildings where occupants often lack control over ventilation and shading systems. This research investigates the relationship between environmental factors, building-related factors, and PAQ in office settings. A field study was conducted in an office building in Bolzano (northern Italy). Carbon dioxide (CO2), particulate matter (PM1, PM2.5, PM10), total volatile organic compounds (TVOC), air temperature, and RH were continuously monitored for a 5-week period during winter 2023. PAQ was assessed through a "right-here right-now" questionnaire using a 7-point Likert scale (from ―very dissatisfied‖ to ―very satisfied‖). Fifty-five individuals participated voluntarily, and their subjective feedback was correlated with thermal and indoor air quality (IAQ) parameters and building-related factors using a multiple linear regression analysis. Results showed that low RH values are associated with greater dissatisfaction with PAQ, while lower temperature values are linked to higher satisfaction with PAQ. Among the air contaminants, PM10 and PM2.5 have statistically significant effects, with higher levels associated with lower satisfaction ratings. Orientation and office facing also influence PAQ satisfaction, with an outdoor view being more favorable than an indoor courtyard view, and a west orientation being the least favorable. The study demonstrates complex relationships between these predictors, their interactions, and PAQ satisfaction.
2024
Investing In Well-Being in a Challenging Future Proceedings of 2024 CATE Conference, 20-22 November 2024 Seville, Spain
Seville, Spain
Ecohouse Initative Ltd
978-1-9161876-7-2
Torriani, G; Torresin, S; Lara-Ibeas, I; Albatici, R; Babich, F
Influence of Indoor Air Pollutants, Temperature, Relative Humidity and Building-Related Factors on Perceived Air Quality (PAQ) in Office Buildings: Evidence from a Field Study / Torriani, G; Torresin, S; Lara-Ibeas, I; Albatici, R; Babich, F. - (2024), pp. 96-96. (Intervento presentato al convegno CATE 2024 tenutosi a Seville, Spain nel 20-22 November 2024).
File in questo prodotto:
File Dimensione Formato  
2025_01_22 CATE 2024.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.48 MB
Formato Adobe PDF
4.48 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/461612
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact