CSP power plants are usually installed in desert regions due to the high availability of direct normal irradiance during the year. This usually entails the unavailability of water to be used for condensation in Rankine cycle and the consequent choice of air-cooled condensers (ACCs) [1]. When dealing with ACCs the main mechanical component is the fan, that drives fresh air towards the heat exchangers driving all the process. The main characteristic of this fan is its size that spans from 7 to 13 m of external diameters, thus resulting in a series of technical problems to be addressed. Such high-volume and low speed fans present critical problem during the testing phase [2]. This dissertation focuses on the certification of fan performance, that follows ISO 5801 [3].

Numerical investigation of CSP air cooled condenser fan / Tieghi, L.; Delibra, G.; Corsini, A.; Van Der Spuy, J.. - In: E3S WEB OF CONFERENCES. - ISSN 2267-1242. - 197:(2020). (Intervento presentato al convegno 75th National ATI congress - #7 clean energy for all, ATI 2020 tenutosi a Virtual, Online nel 2-4/09/2020) [10.1051/e3sconf/202019711010].

Numerical investigation of CSP air cooled condenser fan

Tieghi L.;
2020-01-01

Abstract

CSP power plants are usually installed in desert regions due to the high availability of direct normal irradiance during the year. This usually entails the unavailability of water to be used for condensation in Rankine cycle and the consequent choice of air-cooled condensers (ACCs) [1]. When dealing with ACCs the main mechanical component is the fan, that drives fresh air towards the heat exchangers driving all the process. The main characteristic of this fan is its size that spans from 7 to 13 m of external diameters, thus resulting in a series of technical problems to be addressed. Such high-volume and low speed fans present critical problem during the testing phase [2]. This dissertation focuses on the certification of fan performance, that follows ISO 5801 [3].
2020
75° National ATI Congress proceedings
Rome, Italy
EDP Sciences
Tieghi, L.; Delibra, G.; Corsini, A.; Van Der Spuy, J.
Numerical investigation of CSP air cooled condenser fan / Tieghi, L.; Delibra, G.; Corsini, A.; Van Der Spuy, J.. - In: E3S WEB OF CONFERENCES. - ISSN 2267-1242. - 197:(2020). (Intervento presentato al convegno 75th National ATI congress - #7 clean energy for all, ATI 2020 tenutosi a Virtual, Online nel 2-4/09/2020) [10.1051/e3sconf/202019711010].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/439822
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact