Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
The High Energy Particle Detector (HEPD) is one of the scientific payloads of the China Seismo-Electromagnetic Satellite (CSES). The first satellite of the constellation was launched in February 2018 and has been operational in nominal conditions since then. With the launch of the CSES-02 scheduled for mid 2022, the realization of the HEPD-02 detector is ongoing. The Limadou collaboration, in charge of the payload, updated the HEPD design to improve its performance. A Monte Carlo simulation has been developed using the GEANT4 tool, in order to study the response of the new detector to protons, electrons and light nuclei and validate the new design. The comparison between simulation results and data collected during tests will also allow to calibrate the detector response and to train a specifically designed neural network for event reconstruction. We report preliminary results from the simulation and show that the updated HEPD meets the scientific requirements of the CSES-02 mission.
Expected performance of the High-Energy Particle Detector on-board the second China Seismo-electromagnetic Satellite / Follega, F. M.; Iuppa, R.; Oliva, A.; Pozzato, M.; Ricci, E.; Sahnoun, Z.; Bartocci, S.; Battiston, R.; Benotto, F.; Beole, S.; Burger, W. J.; Campana, D.; Castellini, G.; Cipollone, P.; Coli, S.; Conti, L.; Contin, A.; Cristoforetti, M.; De Cilladi, L.; De Donato, C.; De Santis, C.; Follega, F. M.; Gebbia, G.; Iuppa, R.; Lolli, M.; Marcelli, N.; Martucci, M.; Masciantonio, G.; Merge, M.; Mese, M.; Neubuser, C.; Nozzoli, F.; Oliva, A.; Osteria, G.; Pacini, L.; Palma, F.; Palmonari, F.; Parmentier, A.; Perfetto, F.; Picozza, P.; Piersanti, M.; Pozzato, M.; Ricci, E.; Ricci, M.; Ricciarini, S. B.; Scotti, V.; Sotgiu, A.; Sparvoli, R.; Vitale, V.; Zoffoli, S.; Zuccon, P.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - 395:(2022). (Intervento presentato al convegno 37th International Cosmic Ray Conference, ICRC 2021 tenutosi a deu nel 2021).
Expected performance of the High-Energy Particle Detector on-board the second China Seismo-electromagnetic Satellite
The High Energy Particle Detector (HEPD) is one of the scientific payloads of the China Seismo-Electromagnetic Satellite (CSES). The first satellite of the constellation was launched in February 2018 and has been operational in nominal conditions since then. With the launch of the CSES-02 scheduled for mid 2022, the realization of the HEPD-02 detector is ongoing. The Limadou collaboration, in charge of the payload, updated the HEPD design to improve its performance. A Monte Carlo simulation has been developed using the GEANT4 tool, in order to study the response of the new detector to protons, electrons and light nuclei and validate the new design. The comparison between simulation results and data collected during tests will also allow to calibrate the detector response and to train a specifically designed neural network for event reconstruction. We report preliminary results from the simulation and show that the updated HEPD meets the scientific requirements of the CSES-02 mission.
Follega, F. M.; Iuppa, R.; Oliva, A.; Pozzato, M.; Ricci, E.; Sahnoun, Z.; Bartocci, S.; Battiston, R.; Benotto, F.; Beole, S.; Burger, W. J.; Campana, D.; Castellini, G.; Cipollone, P.; Coli, S.; Conti, L.; Contin, A.; Cristoforetti, M.; De Cilladi, L.; De Donato, C.; De Santis, C.; Follega, F. M.; Gebbia, G.; Iuppa, R.; Lolli, M.; Marcelli, N.; Martucci, M.; Masciantonio, G.; Merge, M.; Mese, M.; Neubuser, C.; Nozzoli, F.; Oliva, A.; Osteria, G.; Pacini, L.; Palma, F.; Palmonari, F.; Parmentier, A.; Perfetto, F.; Picozza, P.; Piersanti, M.; Pozzato, M.; Ricci, E.; Ricci, M.; Ricciarini, S. B.; Scotti, V.; Sotgiu, A.; Sparvoli, R.; Vitale, V.; Zoffoli, S.; Zuccon, P.
Expected performance of the High-Energy Particle Detector on-board the second China Seismo-electromagnetic Satellite / Follega, F. M.; Iuppa, R.; Oliva, A.; Pozzato, M.; Ricci, E.; Sahnoun, Z.; Bartocci, S.; Battiston, R.; Benotto, F.; Beole, S.; Burger, W. J.; Campana, D.; Castellini, G.; Cipollone, P.; Coli, S.; Conti, L.; Contin, A.; Cristoforetti, M.; De Cilladi, L.; De Donato, C.; De Santis, C.; Follega, F. M.; Gebbia, G.; Iuppa, R.; Lolli, M.; Marcelli, N.; Martucci, M.; Masciantonio, G.; Merge, M.; Mese, M.; Neubuser, C.; Nozzoli, F.; Oliva, A.; Osteria, G.; Pacini, L.; Palma, F.; Palmonari, F.; Parmentier, A.; Perfetto, F.; Picozza, P.; Piersanti, M.; Pozzato, M.; Ricci, E.; Ricci, M.; Ricciarini, S. B.; Scotti, V.; Sotgiu, A.; Sparvoli, R.; Vitale, V.; Zoffoli, S.; Zuccon, P.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - 395:(2022). (Intervento presentato al convegno 37th International Cosmic Ray Conference, ICRC 2021 tenutosi a deu nel 2021).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/379050
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.