This paper deals with two different techniques for the establishment of the optimal calibration intervals of Cesium atomic clocks. In particular, the intervals obtained using a mathematical model derived from a metrological analysis are compared with those calculated with an iterative technique referred to as Simple Response Method (SRM). The remarkable consistency between the results achieved with these different methods, not only provides an experimental cross-validation of both techniques, but it also allows the definition of two interchangeable criteria to ensure the status of metrological confirmation of any atomic clock of this type. Moreover, the general features of the SRM pave the way to further possible applications of this method, which is particularly suitable whenever the amount of data measured by a given instrument is not large enough to model its behavior exactly.

Accuracy comparison between techniques for the establishment of calibration intervals: application to atomic clocks / Macii, D., P., T., E., P., P., C., Petri, D.. - STAMPA. - 1:(2003), pp. 458-462. (Proceedings of the 20th IEEE Information and Measurement Technology Conference Vail, USA 20-22 Maggio 2003) [10.1109/IMTC.2003.1208200].

Accuracy comparison between techniques for the establishment of calibration intervals: application to atomic clocks

Macii, David;Petri, Dario
2003-01-01

Abstract

This paper deals with two different techniques for the establishment of the optimal calibration intervals of Cesium atomic clocks. In particular, the intervals obtained using a mathematical model derived from a metrological analysis are compared with those calculated with an iterative technique referred to as Simple Response Method (SRM). The remarkable consistency between the results achieved with these different methods, not only provides an experimental cross-validation of both techniques, but it also allows the definition of two interchangeable criteria to ensure the status of metrological confirmation of any atomic clock of this type. Moreover, the general features of the SRM pave the way to further possible applications of this method, which is particularly suitable whenever the amount of data measured by a given instrument is not large enough to model its behavior exactly.
2003
Proceedings of the 20th IEEE Instrumentation Technology Conference
Piscataway, NJ, USA
IEEE-INST Electrical Electronics Engineers
0780377052
Macii, David; P., Tavella; E., Perone; P., Carbone; Petri, Dario
Accuracy comparison between techniques for the establishment of calibration intervals: application to atomic clocks / Macii, D., P., T., E., P., P., C., Petri, D.. - STAMPA. - 1:(2003), pp. 458-462. (Proceedings of the 20th IEEE Information and Measurement Technology Conference Vail, USA 20-22 Maggio 2003) [10.1109/IMTC.2003.1208200].
File in questo prodotto:
File Dimensione Formato  
Atomic_clock_conf.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 326.3 kB
Formato Adobe PDF
326.3 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/34321
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex 1
social impact