In this paper an investigation campaign, carried out in occasion of the restoration of a timber floor in the Belasi Castle (Trentino, Italy), is reported. In order to validate a testing procedure for the calibration and control of an innovative wood-wood strengthening technique, results of tests performed in situ on the structural elements, in both the original and the repaired condition, have been compared with those obtained in laboratory on some dismantled beams. For the characterization of the material decay, both local mechanical and global vibrational testing have been carried out. For the mechanical characterization of the beams, before and after repair, direct static bending tests have been performed, with distributed loads, on site, and according to standard four-points loading schemes, in laboratory.
Comparison of in situ and laboratory testing for the characterization of old timber beams before and after intervention / Piazza, Maurizio; Riggio, Maria Paola; Tomasi, Roberto; Giongo, Ivan. - 133-134:(2010), pp. 1101-1106. (Intervento presentato al convegno SAHC 2010 tenutosi a Shanghai nel 6th-8th October, 2010).
Comparison of in situ and laboratory testing for the characterization of old timber beams before and after intervention
Piazza, Maurizio;Riggio, Maria Paola;Tomasi, Roberto;Giongo, Ivan
2010-01-01
Abstract
In this paper an investigation campaign, carried out in occasion of the restoration of a timber floor in the Belasi Castle (Trentino, Italy), is reported. In order to validate a testing procedure for the calibration and control of an innovative wood-wood strengthening technique, results of tests performed in situ on the structural elements, in both the original and the repaired condition, have been compared with those obtained in laboratory on some dismantled beams. For the characterization of the material decay, both local mechanical and global vibrational testing have been carried out. For the mechanical characterization of the beams, before and after repair, direct static bending tests have been performed, with distributed loads, on site, and according to standard four-points loading schemes, in laboratory.File | Dimensione | Formato | |
---|---|---|---|
2010-SAHC-Pia-Rig-Gion-Tom-BELASI.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.01 MB
Formato
Adobe PDF
|
1.01 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione