The development of far-offshore wind farms and other large-scale renewable energy sources at long distances from load centers will rely on HVDC transmission. Due to the capability for operation in isolated AC grids and integration into multi-terminal DC grids (MTDC), Voltage Source Converters (VSCs) are becoming the preferred technology for HVDC systems. However, most HVDC transmission schemes are currently constructed as point-to point connections, and there is not yet any clear standardization of voltage levels. Thus, DC/DC converters will become necessary if existing or emerging HVDC links should later be interconnected into MTDC configurations. DC/DC converters might also be needed for power flow control in meshed MTDC grids. In this paper, the general requirements for DC/DC converters in different MTDC grid configurations are briefly analyzed before particular attention is dedicated to converters without galvanic separation for power flow control in meshed MTDC grids. The control and operation of a 4-quadrant DC/DC converter for power flow control with voltage ratio close to unity is then analyzed and demonstrated by simulations in a 4-terminal configuration based on the Cigré DC grid test system.

Analysis of DC/DC Converters in Multiterminal HVDC Systems for Large Offshore Wind Farms / Kolparambath, S.K., Suul, J.A., Tedeschi, E.. - (2015), pp. 415-420. (TAP Energy Kollam, India 24-26 June 2015) [10.1109/TAPENERGY.2015.7229655].

Analysis of DC/DC Converters in Multiterminal HVDC Systems for Large Offshore Wind Farms

Tedeschi E
2015-01-01

Abstract

The development of far-offshore wind farms and other large-scale renewable energy sources at long distances from load centers will rely on HVDC transmission. Due to the capability for operation in isolated AC grids and integration into multi-terminal DC grids (MTDC), Voltage Source Converters (VSCs) are becoming the preferred technology for HVDC systems. However, most HVDC transmission schemes are currently constructed as point-to point connections, and there is not yet any clear standardization of voltage levels. Thus, DC/DC converters will become necessary if existing or emerging HVDC links should later be interconnected into MTDC configurations. DC/DC converters might also be needed for power flow control in meshed MTDC grids. In this paper, the general requirements for DC/DC converters in different MTDC grid configurations are briefly analyzed before particular attention is dedicated to converters without galvanic separation for power flow control in meshed MTDC grids. The control and operation of a 4-quadrant DC/DC converter for power flow control with voltage ratio close to unity is then analyzed and demonstrated by simulations in a 4-terminal configuration based on the Cigré DC grid test system.
2015
2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)
Piscataway, New Jersey, United States
IEEE Institute of Electrical and Electronics Engineers Inc.
978-1-4799-8280-6
978-1-4799-8279-0
Kolparambath, S K; Suul, J A; Tedeschi, E
Analysis of DC/DC Converters in Multiterminal HVDC Systems for Large Offshore Wind Farms / Kolparambath, S.K., Suul, J.A., Tedeschi, E.. - (2015), pp. 415-420. (TAP Energy Kollam, India 24-26 June 2015) [10.1109/TAPENERGY.2015.7229655].
File in questo prodotto:
File Dimensione Formato  
Analysis_of_DC_DC_Converters_in_MTDC_systems_for_large_offshore_WF.pdf

Solo gestori archivio

Descrizione: TAP Energy - conference paper
Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/336446
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
  • OpenAlex 7
social impact