In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the systems presented above, the need to use more and more switched power converters has arisen. The main problem of the connection of multiple controlled switched converters acting as source and load is the degradation of stability that occurs on the DC distribution bus due to the converter interactions. To study the stability in the distribution bus there are some well-established criteria. These criteria require knowledge of the input impedance of the converters that act as load and the output impedance of the equipment that acts as source. In order to reduce the complexity of obtaining the input impedance a model based on a controlled converter acting as a constant power load (CPL) is commonly used. This article studies the accuracy of this model for a commonly used topology in distribution systems nowadays, Two Level Voltage Source Converter (2L-VSC), studying different scenarios that make the model become inaccurate.

Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters / Santamargarita, D.; Huerta, F.; Sanz, M.; Lazaro, A.; D'Arco, S.; Sanchez, S.; Tedeschi, E.; Roldan, J.. - 2019-:(2019), pp. 2026-2031. (Intervento presentato al convegno 45th Annual Conference of the IEEE Industrial Electronics Society, IECON 2019 tenutosi a Lisbon Congress Center, prt nel 2019) [10.1109/IECON.2019.8926942].

Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters

Tedeschi E.;
2019-01-01

Abstract

In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the systems presented above, the need to use more and more switched power converters has arisen. The main problem of the connection of multiple controlled switched converters acting as source and load is the degradation of stability that occurs on the DC distribution bus due to the converter interactions. To study the stability in the distribution bus there are some well-established criteria. These criteria require knowledge of the input impedance of the converters that act as load and the output impedance of the equipment that acts as source. In order to reduce the complexity of obtaining the input impedance a model based on a controlled converter acting as a constant power load (CPL) is commonly used. This article studies the accuracy of this model for a commonly used topology in distribution systems nowadays, Two Level Voltage Source Converter (2L-VSC), studying different scenarios that make the model become inaccurate.
2019
IECON Proceedings (Industrial Electronics Conference)
Piscataway, New Jersey, United States
IEEE
978-1-7281-4878-6
Santamargarita, D.; Huerta, F.; Sanz, M.; Lazaro, A.; D'Arco, S.; Sanchez, S.; Tedeschi, E.; Roldan, J.
Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters / Santamargarita, D.; Huerta, F.; Sanz, M.; Lazaro, A.; D'Arco, S.; Sanchez, S.; Tedeschi, E.; Roldan, J.. - 2019-:(2019), pp. 2026-2031. (Intervento presentato al convegno 45th Annual Conference of the IEEE Industrial Electronics Society, IECON 2019 tenutosi a Lisbon Congress Center, prt nel 2019) [10.1109/IECON.2019.8926942].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/335818
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact