This paper deals with the utilization of the energy storage capacity, inherently present in the Modular Multilevel Converter (MMC), in providing ancillary services to ac grids. The service considered in this paper is Power Oscillation Damping (POD), which requires active power injection and hence, causes distortion (oscillation) in the dc voltage. In a multi-terminal or meshed dc grid, the oscillation is compensated by active power taken from other terminal participating in dc voltage regulation. This action leads to propagation of the oscillation into other connected ac grids, which is undesirable. This can be avoided or reduced if the power injection is taken from the arm capacitors of the MMC. Such utilization of the MMC energy storage has already been proposed in literature. However, the amount of power that can be injected from one converter is very limited. Therefore, this paper proposes a method to coordinate such a functionality among multiple MMC terminals with the aim of obtaining higher capacity to accommodate more demanding services. Furthermore, communication between the terminals is not required because local measurement of the dc voltage is used as a feedback signal.

Coordination of modular multilevel converter based HVDC terminals for ancillary services / Taffese, A.A., Tedeschi, E.. - (2018). (20th Power Systems Computation Conference, PSCC 2018 Dublino, Irlanda 11-15 giugno 2018) [10.23919/PSCC.2018.8442864].

Coordination of modular multilevel converter based HVDC terminals for ancillary services

Tedeschi E
2018-01-01

Abstract

This paper deals with the utilization of the energy storage capacity, inherently present in the Modular Multilevel Converter (MMC), in providing ancillary services to ac grids. The service considered in this paper is Power Oscillation Damping (POD), which requires active power injection and hence, causes distortion (oscillation) in the dc voltage. In a multi-terminal or meshed dc grid, the oscillation is compensated by active power taken from other terminal participating in dc voltage regulation. This action leads to propagation of the oscillation into other connected ac grids, which is undesirable. This can be avoided or reduced if the power injection is taken from the arm capacitors of the MMC. Such utilization of the MMC energy storage has already been proposed in literature. However, the amount of power that can be injected from one converter is very limited. Therefore, this paper proposes a method to coordinate such a functionality among multiple MMC terminals with the aim of obtaining higher capacity to accommodate more demanding services. Furthermore, communication between the terminals is not required because local measurement of the dc voltage is used as a feedback signal.
2018
2018 Power Systems Computation Conference (PSCC)
New York
Institute of Electrical and Electronics Engineers (IEEE)
9781910963104
Taffese, A A; Tedeschi, E
Coordination of modular multilevel converter based HVDC terminals for ancillary services / Taffese, A.A., Tedeschi, E.. - (2018). (20th Power Systems Computation Conference, PSCC 2018 Dublino, Irlanda 11-15 giugno 2018) [10.23919/PSCC.2018.8442864].
File in questo prodotto:
File Dimensione Formato  
2018_Coordination_of_MMCs_PSCC_Taffese_2018.pdf

Solo gestori archivio

Tipologia: Post-print referato (Refereed author’s manuscript)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.32 MB
Formato Adobe PDF
1.32 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/272665
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex 2
social impact