In the framework of the PixFEL project, a processing channel for pixel sensor readout has been designed and fabricated in a 65 nm CMOS technology. The detector under development is aimed at applications to coherent X-ray diffraction imaging (CXDI) at the next generation free electron lasers (FELs). Especially in the detector region around the hole for the unscattered photon beam, pixels will be subjected to huge doses of ionizing radiation, in the order of tens of Grad(SiO 2 , during their lifetime. The total ionizing dose (TID) for the frontend electronics, while significantly reduced by the shielding effect of the detector, is still expected to exceed one Grad(SiO 2 . This paper investigates the performance degradation in the PixFEL readout circuit, in particular in the charge sensitive amplifier, after exposure to X-ray doses up to 100 Mrad(SiO 2 .

The PixFEL front-end for X-ray imaging in the radiation environment of next generation FELs / Ratti, L., Comotti, D., Fabris, L., Grassi, M., Lodola, L., Malcovati, P., Manghisoni, M., Re, V., Traversi, G., Vacchi, C., Batignani, G., Bettarini, S., Casarosa, G., Forti, F., Morsani, F., Paladini, A., Paoloni, E., Rizzo, G., Benkechkache, M.A., Dalla Betta, G.-F., et al.. - ELETTRONICO. - (2017), pp. 1-4. (2017 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2017 Atlanta, USA 2017) [10.1109/NSSMIC.2017.8533009].

The PixFEL front-end for X-ray imaging in the radiation environment of next generation FELs

Dalla Betta, G. -F.;Mendicino, R.;Pancheri, L.;Verzellesi, G.;Xu, H.
2017-01-01

Abstract

In the framework of the PixFEL project, a processing channel for pixel sensor readout has been designed and fabricated in a 65 nm CMOS technology. The detector under development is aimed at applications to coherent X-ray diffraction imaging (CXDI) at the next generation free electron lasers (FELs). Especially in the detector region around the hole for the unscattered photon beam, pixels will be subjected to huge doses of ionizing radiation, in the order of tens of Grad(SiO 2 , during their lifetime. The total ionizing dose (TID) for the frontend electronics, while significantly reduced by the shielding effect of the detector, is still expected to exceed one Grad(SiO 2 . This paper investigates the performance degradation in the PixFEL readout circuit, in particular in the charge sensitive amplifier, after exposure to X-ray doses up to 100 Mrad(SiO 2 .
2017
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2017 - Conference Proceedings
Piscataway, NJ
Institute of Electrical and Electronics Engineers Inc.
9781538622827
Ratti, L.; Comotti, D.; Fabris, L.; Grassi, M.; Lodola, L.; Malcovati, P.; Manghisoni, M.; Re, V.; Traversi, G.; Vacchi, C.; Batignani, G.; Bettarini,...espandi
The PixFEL front-end for X-ray imaging in the radiation environment of next generation FELs / Ratti, L., Comotti, D., Fabris, L., Grassi, M., Lodola, L., Malcovati, P., Manghisoni, M., Re, V., Traversi, G., Vacchi, C., Batignani, G., Bettarini, S., Casarosa, G., Forti, F., Morsani, F., Paladini, A., Paoloni, E., Rizzo, G., Benkechkache, M.A., Dalla Betta, G.-F., et al.. - ELETTRONICO. - (2017), pp. 1-4. (2017 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2017 Atlanta, USA 2017) [10.1109/NSSMIC.2017.8533009].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/230527
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex 0
social impact